Filename: O&M/SPM
Operations & Maintenance Manual
Model: SPM504
Premium Brushless Solder Pure Multi User Fume Capture
1.0
IMPORTANT:
Save shipping box and foam for future service. Shipping without proper foam will cause damage to unit.
2.0
SAFETY PRECAUTIONS
Carefully read instructions in this manual before operation (keep manual as it contains information for proper operation and maintenance). Keep all fastening hardware
tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which the special filter is removed, installed, and serviced. Filter must be in
place whenever this machine is in operation. Use only on grounded electrical circuit; do not use two-wire electrical prong adapters to defeat the three-pronged plug on
the end of the cord. When servicing motor, be careful when touching exterior of motor when it is turned off; it may be hot enough to be painful or cause injury.
Do not
substitute any other filter for the one supplied, as it will alter the design characteristics. UNPLUG UNIT FROM ITS POWER SUPPLY PRIOR TO SERVICING!
3.0
SYSTEM COMPONENTS
Description
SPM504-1
SPM504-2
SPM504-3
SPM504-4
SPM504-5
Airflow (Free Air)
475
475
475
475
475
Stage 1 Filter (Dust)
F265
F007
F007
F007
F007
Stage 2 Filter (HEPA)
F357
F357
F022
F357
n/a
Stage 3 Filter (ODOR)
F033-GPC
F045-GPC
F033-GPC
F045-GPC
F033-GPC (2x)
Dimensions, Height:
30” (762mm)
30” (762mm)
30” (762mm)
30” (762mm)
30” (762mm)
Dimensions, Width:
23” (585mm)
23” (585mm)
23” (585mm)
23” (585mm)
23” (585mm)
Dimensions Depth:
15” (381mm)
15” (381mm)
15” (381mm)
15” (381mm)
15” (381mm)
Voltage / Current:
120/1/60, 9.2amps
120/1/60, 9.2amps
120/1/60, 9.2amps
120/1/60, 9.2amps
120/1/60, 9.2amps
Max. Power, approx. Weight:
740watts, 180lbs (82kgs)
740watts, 180lbs (82kgs)
740watts, 180lbs (82kgs)
740watts, 180lbs (82kgs)
740watts, 180lbs (82kgs)
4.0
UNIT INSPECTION
Upon receipt, inspect unit for either visible or concealed damage. Damage should be immediately reported to the transport company.
If you suspect concealed damages inside the box indicate so on the transport companies’ shipping documents.
5.0 ASSEMBLY
Unit is shipped in 1 box:
- Remove cardboard packaging
- Lift unit off the pallet and place is required location
-
Open Front Filter door, remove Manual, Power cord set AND REMOVE PLASTIC from HEPA Filter
6.0
PRE START-UP CHECKLIST
a)
Check that all internal components are present and are adequately supported;
b)
Open Front Filter Access Door and ensure filters are positioned as per photo below
c)
Check that labels and serial numbers are present for future identification;
d)
Verify power supply is compatible with equipment (120-volt/1 phase/60hz). Check that the unit is plugged into a grounded receptacle;
e)
Ensure that rubber grommets are tight and secure prior to placing unit on the floor.
7.0
START-UP
a)
Ensure door closes tightly; b)
Insert male end of cord into wall outlet. Unit should be connected to an independent circuit;
c)
Switch power toggle to "ON" position to ensure system operation.
WARNING: DO NOT OPERATE UNIT UNLESS FILTER IS IN PLACE.