QF1200S; edition 2016-05; page 5 of 24   

 

Please note: 

The direction of flow can be adjusted by turning the pump chamber in 90° steps.  
 
The Quattroflow 1200S is self-priming and can run dry. Inside the pump chamber there are no rotating 
parts that might cause heating up of the product or shed particles.  
 
The pump-motor unit is mounted on a stainless steel base plate. In case that the pump will not be 
mounted on the base plate but in a frame or any other base measures have to be taken that there will 
be a proper alignment of the motor and the pump. 
 

2.3. Start-up 

 
Before start-up of the pump anyone should acquaint oneself with the explanations of the chapter 
troubleshooting (see page 18). Only by this the defect quickly can be realized and eliminated in case 
of trouble. Problems which cannot be solved or with an unknown reason should be passed on to the 
manufacturer. 
 
Prior to each use we recommend to flush the pump with a proper fluid (e.g. water or buffer). 
 
Prior to the very first use it might make sense to clean and sanitize the pump chamber. A commercial 
caustic cleaner and/or 0.1N to 0.5N NaOH can be applied. The chosen cleaning agent can be 
recirculated and also stored inside the pump chamber. For flushing out of any cleaning agent do not 
recirculate! Check with appropriate analytical methods the success of the flushing procedure.. 
 

 

Recommendation: Test run prior first use! 

 
Before using your pump in your process perform a test run to get used to the specific 
properties of the pump. 
 
 

Please note:

  ALMATEC Maschinenbau GmbH is also building custom-made pumps and set-ups. 

These modified pumps can be different from this one that is described in here. However the basic 
information is applicable to all of the Quattroflow 1200S Series pumps. Please do not hesitate to 
contact us for further information. 
 

 

Pay attention to a sufficiently dimensioned piping. A too small piping of the 
suction line can cause cavitation as well as a loss of performance.  
If hoses were used in the suction line, make sure that they do not collapse due 
to the negative pressure. 
 
When installing the pump please consider that around the pump enough space 
is available for operation and maintenance. Pay attention to the required space 
needed for assembly and disassembly of the pump chamber (see 4.1.1.). 
 
During start-up pay attention to the warning and safety instructions of the 
following chapter 3 of this manual.

 

 

 

 

 

Summary of Contents for 1200S

Page 1: ...a are of a ope At d the w Orig and tructi 00S Qu Piston ultiple U eft hand and odel image m ersions are p l carefu an appr rating s ttentio warning inal In Insta ions uaterna Diaph Use with separa mid...

Page 2: ...ety instructions for maintenance inspection and mounting operations 10 3 7 Unauthorized reconstruction and spare part usage 10 3 8 Inadmissible modes of operation 10 3 9 Further warning and safety ins...

Page 3: ...and mechanical influences The following storage conditions are recommended Steady ventilated dust and vibration free storage room Ambient temperature between 15 C 59 F and 25 C 77 F with a relative hu...

Page 4: ...omatography columns Feed pump to mix gradients Feed pump for centrifuges or separators Feed pump for homogenizers Feed pump for filling machines 2 2 General description of the machine The Quattroflow...

Page 5: ...aOH can be applied The chosen cleaning agent can be recirculated and also stored inside the pump chamber For flushing out of any cleaning agent do not recirculate Check with appropriate analytical met...

Page 6: ...00S CV via the control panel Display show rpm V max speed 2 200 rpm Main switch Push to start the panel lights up Push to speed up arrow bottom up or to speed down arrow top down Push Green button RUN...

Page 7: ...ersonnel should change the parameter of the control panel on the back of the panel via DIP switches Attention Pay attention to the separate operating instructions of the ENGEL Motor QF1200S HT Pumpe M...

Page 8: ...we recommend the following steps 1 CIP of the pump chamber according to 2 4 or any other suitable process 2 Empty the pump 3 Remove the pump chamber from the pump drive see 4 1 1 4 Close in and outlet...

Page 9: ...strictly the safety guidelines of this manual as well as all national and possible internal regulations e g the handling of chemicals like caustic or acid the handling of biological materials the han...

Page 10: ...tart up and check the tightness of the pump o Please respect the relevant additional security advices if the pump has been used for aggressive dangerous or toxic liquids e g suitable protective equipm...

Page 11: ...the right tool for the specific application The user operator is responsible to perform a proper method of testing if the pump should be applied for his specific application The chemical and thermal c...

Page 12: ...led personnel Check the electrical cables before connecting to mains supply During all maintenance work it has to be ensured that no explosive atmosphere can arise Appropriate protection equipment is...

Page 13: ...rate SIP etc it may be necessary to shorten the maintenance intervals for the elastomers significantly In case that the diaphragm broke it needs to be replaced Then it is also recommended to check the...

Page 14: ...lves can be conducted by the operator The following drawings describe it step by step maintenance kit PSKITQF12MU In case of bursting diaphragms by overpressure we advice also to change the bearing un...

Page 15: ...he following torque values Image 10 Bolts pump chamber 10 Nm 7 4 lb ft Image 10 Bolts diaphragm cover housing 5 Nm 3 7 lb ft Image 12 Bolt clamping ring 6 Nm 4 4 lb ft Turn the pump chamber until you...

Page 16: ...eccentric shaft or Maintenance kit PSKITWLC125 5 eccentric shaft for QF1200S and QF1200S HT or Maintenance kit PSKITWLC125 CV QF1200S CV The replacement of the bearing unit can be conducted by the op...

Page 17: ...r 10 Nm 7 4 lb ft Image 9 Bolt clamping ring 6 Nm 4 4 lb ft gap 1 5 mm 0 079 0 118 inch 11 Turn the pump chamber until you see the screw of the clamping ring and fix it with 5mm hex key with a torque...

Page 18: ...h size10 remove screws 1 Dismounting drive house Fitting 4x M6 wrench size10 screws with washer 1 Mounting of drive house 4 3 Disassembly assembly of the drive housing For further questions and orderi...

Page 19: ...X Pressure line completely or partly clogged diaphragm maybe broken change diaphragm 10 X The diameter of the pipes in suction or pressure line are too small 11 X Check the coupling halves They must...

Page 20: ...pump Pump rpm motor rpm If reducer gear drives are used Pump rpm motor rpm x reduction ratio 6 1 Performance standard version Eccentric shaft 3 0 10 20 30 40 50 60 70 80 0 2 4 6 8 10 12 14 0 100 200...

Page 21: ...selected motor frequency drive combination the motor frequency and the resulting pump speed might differ 0 10 20 30 40 50 60 70 80 0 2 4 6 8 10 12 14 16 18 20 22 0 200 400 600 800 1000 1200 1400 0 500...

Page 22: ...ter t ct model w 0 psi 2 arts above w he final asse ct model w 0 psi 2 arts above w he final asse with integr 29 psi 58 ps were ascertai embly of the with integr 29 psi 58 ps were ascertai embly of th...

Page 23: ...pends on installation position ca 8 26 depends on inst position ca 8 26 depends on inst position ca 8 26 depends on inst position Product wetted surface approx cm inch 367 57 367 57 367 57 367 57 Spee...

Page 24: ...d into separate Control Box Power Supply Unit separate Controller integrated in pump Power Supply Unit integrated in pump Manufacturer standard Lenze AC tech TDK Lambda power supply Panasonic Mean Wel...

Reviews: