background image

 

 

  

 

                                                                                                                     

 

QF150S; edition 2016-05; page 6 of 19   

 

2.4. Control panel 
 

In the Quattroflow 150S pump is operated with a 50 W brushless Panasonic motor. You can modify 
the speed of the motor by the control panel on the top of the pump. 

 
Main switch. Push to start – the panel lights up  
 
Push to speed up (arrow bottom-up) or to speed 
down (arrow top down) 
 
Push "Green button" RUN, to start the pump 
 
“MOD button“ Switch between rpm, effiency %, 
motor power V 
 
Display show: "rpm, %, V"  
(max. speed 3.000 rpm) 
 
Push the "Red button" STOP to stop the pump 

 
 

 
Attention: The optimal motor parameter are set by the factory. 
 
Only authorized and qualified personnel should change the parameter of the control panel! 
 

 
Attention!
 

 
You must study the operating instructions of the PANASONIC–Motor before 
you make any changes of the parameter! 
 

 

Quattroflow 150S Pump  
Motor: Panasonic, 50 W, 230V with integrated frequency inverter  

Speed control: Panasonic Digital Control Panel 
 
 

 

2.5. Cleaning (CIP) 

 
Depending on the products in contact with the pump and given requirements the cleaning procedure 
needs to be adapted accordingly. It is the responsibility of the user to verify the cleaning efficiency. 
Safety rules and safety measures like protective glasses, gloves and protective clothing have to be 
followed and used when working with chemicals like sodium hydroxide (NaOH).  
 
As a general rule we recommend to clean the pump according to the following procedure. 

1.  Pre rinse the pump with pure water, until residual amounts of product have been removed. 
2.  Cleaning step with 0.5 M NaOH (ca. 50°C) at 80% of the maximum RPM for 

approximately 30 min. Check before, if surrounding conditions (e.g. pipe diameter, system 
pressure rating) allow to operate the pump at this speed. 

3.  Final rinse with pure water, until neutrality has been achieved (e.g. by measuring 

conductivity or pH of the rinse water). 
 
 

 
 

Summary of Contents for 150s

Page 1: ...trol pa manua are of a ope At d the w Orig and tructi 50S Qu Piston ultiple U anel and hou l carefu an appr rating s ttentio warning inal Ins Insta ions aterna Diaph Use using other v ully befo ropria...

Page 2: ...tructions 8 3 5 Safety hints for the operator 8 3 6 Safety instructions for maintenance inspection and mounting operations 9 3 7 Unauthorized reconstruction and spare part usage 9 3 8 Inadmissible mod...

Page 3: ...nd mechanical influences The following storage conditions are recommended Steady ventilated dust and vibration free storage room Ambient temperature between 15 C 59 F and 25 C 77 F with a relative hum...

Page 4: ...cosmetic research centers or plants Examples Solutions containing proteins albumin IgG Clotting factors monoclonal antibodies enzymes vaccines Solutions of polymers or suspensions silicon latex chroma...

Page 5: ...er Prior to each use we recommend to flush the pump with a proper fluid e g water or buffer Prior to the very first use it might make sense to clean and sanitize the pump chamber A commercial caustic...

Page 6: ...r Panasonic 50 W 230V with integrated frequency inverter Speed control Panasonic Digital Control Panel 2 5 Cleaning CIP Depending on the products in contact with the pump and given requirements the cl...

Page 7: ...max 30 min Follow instructions of the autoclave manufacturer Please make sure that the pump chamber is not placed on the clamp ring during the autoclave process The clamp ring should not be loaded dur...

Page 8: ...strictly the safety guidelines of this manual as well as all national and possible internal regulations e g the handling of chemicals like caustic or acid the handling of biological materials the han...

Page 9: ...art up and check the tightness of the pump o Please respect the relevant additional security advices if the pump has been used for aggressive dangerous or toxic liquids e g suitable protective equipme...

Page 10: ...he right tool for the specific application The user operator is responsible to perform a proper method of testing if the pump should be applied for his specific application The chemical and thermal co...

Page 11: ...led personnel Check the electrical cables before connecting to mains supply During all maintenance work it has to be ensured that no explosive atmosphere can arise Appropriate protection equipment is...

Page 12: ...ecessary to shorten the maintenance intervals for the elastomers significantly In case that the diaphragm broke it needs to be replaced Then it is also recommended to check the ball bearings For corro...

Page 13: ...and the valves can be conducted by the operator The following drawings describe it step by step maintenance kit PSKITQF15MU In case of bursting diaphragms by overpressure we advice also to change the...

Page 14: ...05 page 14 of 19 4 1 3 Assembly of the pump chamber to the ring drive Pay attention to the following torque values Image 2 item 1 Bolts pump chamber 4 Nm 3 lb ft Image 2 item 2 Bolt clamping ring 2 N...

Page 15: ...the bearing unit shaft bearing cap unit kit PSKITWLC155 can be conducted by the operator The following drawings describe it step by step Between both coupling halves has to be a gap of 1 mm 0 039 inc...

Page 16: ...truction in discharge line 9 X Pressure line completely or partly clogged diaphragm maybe broken change diaphragm 10 X The diameter of the pipes in suction or pressure line are too small 11 X Check th...

Page 17: ...p Pump rpm motor rpm The flow rates showing at the chart above were ascertained with new diaphragms and new valves under standard conditions after the final assembly of the pump 0 0 5 1 1 5 2 2 5 3 0...

Page 18: ...face approx cm inch 112 17 112 17 Speed range pump rpm 10 3000 10 3000 Connection specification inlet standard Connector 1 4 TC 1 4 TC Flange diameter mm inch 25 25 Internal diameter mm inch 4 7 4 7 C...

Page 19: ...TDK Lambda power supply Designation n a HWS Analog input optional 0 5V 0 10 V Protection class IP54 IP20 switch board Power supply 230V 50Hz 1P optional 110V 60 Hz 1P 85 265VAC 50 60 Hz 8 2 A Housing...