RADARAY FOUL DETECTOR MANUAL
400-088-006-01 Rev. A
Page 5
2. Remove the Radaray cover.
3. Verify that the lenses on the sensor assembly are aligned vertically. If not, loosen the plastic
nut securing the sensor to the bracket, rotate the unit until the lenses are aligned vertically,
and tighten the nut. Do not overtighten.
4. If beam adjustment is necessary, loosen the two bracket mounting screws slightly, allowing the
optical assembly to move from side to side. Position the assembly until the LED light goes out,
and tighten the screws. The horizontal beam alignment is now complete.
Note
- It is very unlikely that the vertical beam alignment will be incorrect. Apply some slight pressure
on either side of the sensor bracket to determine if it needs to be adjusted. Remember, vertical
adjustment should only be done if the horizontal alignment adjustments do not result in the LED light
turning off. If the vertical alignment is not correct, carefully use a pair of needle nose pliers and slightly
bend the sensor bracket to tilt the sensor up or down as needed.
5. Replace the Radaray cover and test the unit to make sure that everything is still aligned.