background image

 

RADARAY FOUL DETECTOR MANUAL

 

 

400-088-006-01 Rev. A 

Page 5

 

 

2.  Remove the Radaray cover. 

3.  Verify that the lenses on the sensor assembly are aligned vertically. If not, loosen the plastic 

nut securing the sensor to the bracket, rotate the unit until the lenses are aligned vertically, 

and tighten the nut. Do not overtighten. 

4.  If beam adjustment is necessary, loosen the two bracket mounting screws slightly, allowing the 

optical assembly to move from side to side. Position the assembly until the LED light goes out, 

and tighten the screws. The horizontal beam alignment is now complete. 

Note 

- It is very unlikely that the vertical beam alignment will be incorrect. Apply some slight pressure 

on either side of the sensor bracket to determine if it needs to be adjusted. Remember, vertical 

adjustment should only be done if the horizontal alignment adjustments do not result in the LED light 

turning off. If the vertical alignment is not correct, carefully use a pair of needle nose pliers and slightly 

bend the sensor bracket to tilt the sensor up or down as needed.  

 

5.  Replace the Radaray cover and test the unit to make sure that everything is still aligned. 

 

 

 

Summary of Contents for EDGE RADARAY

Page 1: ...EDGE RADARAY Pinspotter Manual Supplement Appendix H These Original Instructions were written in English 400 088 006 01 Rev A June 2022...

Page 2: ......

Page 3: ...e held responsible for any claims resulting from these errors DOCUMENT UPDATES This manual supersedes all previous versions of the EDGE Radaray Owner s Manual QubicaAMF Worldwide LLC reserves the righ...

Page 4: ......

Page 5: ...Radaray Foul Detector Manual 400 088 006 01 Rev A Summary of Changes Change No ECR No Rev A 22 0001 List of Effective Pages Page Change No Effective Date All Rev A 6 10 2022...

Page 6: ......

Page 7: ...RADARAY FOUL DETECTOR MANUAL 400 088 006 01 Rev A Page 1 Appendix H Radaray Foul Detector Manual...

Page 8: ......

Page 9: ...Page 3 Contents Appendix H Radaray Foul Detector Manual 1 1 GENERAL INFORMATION 3 2 INSTALLATION AND ALIGNMENT PROCEDURE 3 2 1 Installation 3 2 2 Alignment Procedure 4 2 3 Single Side Operation 6 3 O...

Page 10: ......

Page 11: ...ounted in the control unit cover and causes a beeper to sound for approximately 13 seconds 2 INSTALLATION AND ALIGNMENT PROCEDURE Reflector Assembly The reflector unit mounts at the end of the common...

Page 12: ...ping 10 x 1 hex head screws provided 4 Before installing the cover complete the alignment procedure in accordance with section 2 2 5 Once aligned insert a lens in each opening in the sides of the cove...

Page 13: ...embly until the LED light goes out and tighten the screws The horizontal beam alignment is now complete Note It is very unlikely that the vertical beam alignment will be incorrect Apply some slight pr...

Page 14: ...for the foul detector is displayed then the foul detector is off Figure 2 Foul Detector Icons Foul Detector On Foul turns light on sounds buzzer and a foul will count for scoring purposes Foul Detect...

Page 15: ...leaning recommendations 1 Use a clean non abrasive cloth to gently wipe the face of the reflectors on the reflector unit and the optics window on the EDGE Radaray base cover 2 If gently wiping does no...

Page 16: ...RADARAY FOUL DETECTOR MANUAL 400 088 006 01 Rev A Page 8...

Page 17: ...88 000 079 LENS FOUL DETECTOR 6 4 088 000 087 PHPMS 1 4 20 X 0 50 BO 7 1 088 000 283 FOUL DETECT WIRE HARNESS 8 1 088 000 221 QAMF XLI RADAR CVR LED BOARD 9 2 088 000 421 FOUL SENSOR BRACKET 10 1 090...

Page 18: ......