Parameter  no.  40  –  Power  reporting  in 
Watts on power change 

Set value means percentage, set value from 0 
- 100=0% - 100%. Available configuration 
parameters (data type is 1 Byte DEC):   

 

default value 3 

 

0 – Reporting Disabled 

 

1 – 100 = 1% - 100% Reporting enabled 
Power  report  is  send  (push)  only  when 
actual power in Watts in real time changes 
for  more  than  set  percentage  comparing 
to previous actual power in Watts, step is 
1%. 

NOTE:

 if power changed is less than 1W, the 

report  is  not  send  (pushed),  independent  of 
percentage set.    

 
Parameter  no.  42  –  Power  reporting  in 
Watts by time interval 

Set  value  means  time  interval  (0  –  65535)  in 
seconds, when power report is send. 
Available  configuration  parameters  (data  type 
is 2 Byte DEC): 

 

default value 300 (power report in Watts is   
send each 300s) 

 

0 – Reporting Disabled 

 

1 – 65535 = 1second – 65535 seconds.   
Reporting  enabled.  Power  report  is  send 
with time interval set by entered value.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Technical Specifications   

 

 

 

Power supply 

110 - 230 VAC ±10% 
50/60Hz, 24-30VDC 

Rated load current of AC 
output (resistive load)* 

1 X 10A / 230VAC 

Rated load current of DC 
output (resistive load) 

1 X 10A / 30VDC 

Output circuit power of 
AC output (resistive 
load) 

2300W (230VAC) 

Output circuit power of 
DC output (resistive 
load) 

240W (24VDC) 

Power measurement 
accuracy 

P=5-50W, +/-3W 
P>50W, +/-3% 

Digital temperature 
sensor range (sensor 
must be ordered 
separately)

 

-50 ~ +125°C 

Operation temperature  -10 ~ +40°C 
Distance 

up to 30 m indoors 
(depending on 
building materials) 

Dimensions (W x H x D)  41,8 x 36,8 x 15,4mm 
Weight 

25g 

Electricity consumption  0,4W 
For installation in boxes  Ø 

 60mm or 2M 

Switching

 

Relay 

* In case of load other than resistive, pay 
attention to the value of cos 

φ

 and if necessary 

apply load lower than the rated load. Max 
current for cos 

φ

=0,4 is 3A at 250VAC, 3A    at 

24VDC L/R=7ms. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Z-Wave Device Class:   

BASIC_TYPE_ROUTING_SLAVE 

GENERIC_TYPE_SWITCH_BINARY 

SPECIFIC_TYPE_POWER_SWITCH_BINARY 

 

Z-Wave Supported Command Classes:   

COMMAND_CLASS_BASIC 
COMMAND_CLASS_SWITCH_BINARY 

COMMAND_CLASS_SWITCH_ALL 

COMMAND_CLASS_METER_V3 
COMMAND_CLASS_SENSOR_MULTILEVEL_V3 

COMMAND_CLASS_MULTI_CHANNEL_V2 

COMMAND_CLASS_POWERLEVEL 
COMMAND_CLASS_ASSOCIATION 

COMMAND_CLASS_CONFIGURATION 

COMMAND_CLASS_MANUFACTURER_SPECIFIC 
COMMAND_CLASS_VERSION 

COMMAND_CLASS_MARK 

COMMAND_CLASS_BASIC 

 
 

Endpoint 1 (I2): 
Device Class: 

GENERIC_TYPE_SENSOR_BINARY 

SPECIFIC_TYPE_NOT_USED 

Command Classes: 

COMMAND_CLASS_SENSOR_BINARY 

COMMAND_CLASS_BASIC 

 

Endpoint 2 (I3): 
Device Class: 

GENERIC_TYPE_SENSOR_BINARY 

SPECIFIC_TYPE_NOT_USED 

Command Classes: 

COMMAND_CLASS_SENSOR_BINARY 

COMMAND_CLASS_BASIC 

 
This product can be included and operated in 
any Z-Wave network with other Z-Wave 
certified devices from any other manufacturers. 
All constantly powered nodes in the same 
network will act as repeaters regardless of the 
vendor in order to increase reliability of the 
network. 
 

 
 
 
 
 
 

 
Important disclaimer 

 
Z-Wave  wireless  communication  is  inherently 
not  always  100%  reliable,  and  as  such,  this 
product  should  not  be  used  in  situations  in 
which  life  and/or  valuables  are  solely 
dependent on its function. 

 

Warning! 

 

Do  not  dispose  of  electrical  appliances  as 
unsorted  municipal  waste,  use  separate 
collection facilities.   
Contact your local government for information 
regarding  the  collection  systems  available.  If 
electrical appliances are disposed of in landfills 
or dumps, hazardous substances can leak into 
the  groundwater  and  get  into  the  food  chain, 
damaging  your  health  and  well-being.  When 
replacing  old  appliances  with  new  once,  the 
retailer  is  legally  obligated  to  take  back  your 
old  appliance  for  disposal  at  least  for  free  of 
charge. 
This user manual is subject to change and 
improvement without notice.

 

 

 

 
 

 

 
 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Qubino

   

Goap d.o.o. Nova Gorica 
Ulica Klementa Juga 007 
5250 Solkan 
Slovenia 
 
E-mail:  

info@qubino.com

   

Tel:       +386 5 335 95 00 
Web:     

www.qubino.com

     

 

   
Date: 8.12.2014   
Document: Qubino_Flush 1 
relay user

 

manual_V6.3_eng                                                                   

 

 

Summary of Contents for Flush 1

Page 1: ...nting box hidden behind a traditional wall switch Module measures power consumption of electrical device and supports connection of digital temperature sensor It is designed to act as repeater in order to improve range and stability of Z wave network Supported switches Module supports mono stable switches push button and bi stable switches The module is factory set to operate with bi stable switch...

Page 2: ...connect the module to loads exceeding recommended values Connect the module only in accordance to the below diagrams Improper connections may be dangerous Package contents Flush 1 relay Electrical diagram 230VAC Notes for the diagram N Neutral lead L Live lead Q Output for electrical device I3 Input for switch push button or sensor I2 Input for switch push button or sensor I1 Input for switch push...

Page 3: ...ule within maximum 1 meter 3 feet of the main controller enable add remove mode on main controller auto inclusion 30 minutes after connected to power supply or press service button S for more than 2 second or N 24VDC L 24VDC Q Output for electrical device I3 Input for switch push button or sensor I2 Input for switch push button or sensor I1 Input for switch push button TS Terminal for digital temp...

Page 4: ...an 2 and less than 6 second module is excluded but configuration parameters are not set to default values Association Association enables Flush 1 relay module to transfer commands inside Z Wave network directly without main controller to other Z Wave modules Associated Groups Group 1 basic on off triggered at change of the output Q state and reflecting its state up to 16 nodes Group 2 basic on off...

Page 5: ...active ALL OFF active 2 ALL ON active ALL OFF is not active Flush 1 relay module responds to commands ALL ON ALL OFF that may be sent by the main controller or by other controller belonging to the system Parameter no 11 Automatic turning off relay after set time Available configuration parameters data type is 2 Byte DEC Default value 0 0 Auto OFF disabled 1 65535 0 01second 655 35 seconds Auto OFF...

Page 6: ...centage comparing to previous actual power in Watts step is 1 NOTE if power changed is less than 1W the report is not send pushed independent of percentage set Parameter no 42 Power reporting in Watts by time interval Set value means time interval 0 65535 in seconds when power report is send Available configuration parameters data type is 2 Byte DEC default value 300 power report in Watts is send ...

Page 7: ...urement accuracy P 5 50W 3W P 50W 3 Digital temperature sensor range sensor must be ordered separately 50 125 C Operation temperature 10 40 C Distance up to 30 m indoors depending on building materials Dimensions W x H x D 41 8 x 36 8 x 15 4mm Weight 25g Electricity consumption 0 4W For installation in boxes Ø 60mm or 2M Switching Relay In case of load other than resistive pay attention to the val...

Page 8: ... COMMAND_CLASS_VERSION COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Endpoint 1 I2 Device Class GENERIC_TYPE_SENSOR_BINARY SPECIFIC_TYPE_NOT_USED Command Classes COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_BASIC Endpoint 2 I3 Device Class GENERIC_TYPE_SENSOR_BINARY SPECIFIC_TYPE_NOT_USED Command Classes COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_BASIC This product can be included and operated in any Z Wave ...

Page 9: ...ailable If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge This user manual is subject to change and improvement without n...

Reviews: