EN
.
33
7.2. Installing the Qubino Temperature Sensor
The temperature sensor is a Qubino accessory and is sold separately - for more info, please
see the Qubino product catalogue or website:
http://qubino.com/products/accessories/
Product ordering code: ZMNHEA1
Qubino Z-Wave devices have the option to connect a temperature sensor (sold separately),
which allows you to
remotely monitor ambient or water temperature
. Qubino devices are the
only Z-Wave devices of its kind to offer this unique capability. With the sensor connected to the
device, you can carry out accurate measurements of room temperature, pool water
temperature, etc. and build automation rules around them. Qubino device with a temperature
sensor is connected directly to power supply. Install it and forget it, there is no need to worry
about changing the batteries like with most other Z-Wave temperature sensors which run on
batteries. The temperature sensor
’s
range is between -50
°
and 125°C
(-58
°
and 257
°
F).
The digital Temperature sensor comes with a 1 m (3.3 ft) cord and a connector to attach it
directly to a Qubino device.
1.
To prevent electrical shock, make sure that no voltage is present on the temperature
sensor cable.
2.
When connected to Qubino device, the temperature sensor is under high voltage, which
is very dangerous.
3.
Goap d.o.o. does not take responsibility for any damage or electrical shock due to
incorrect sensor assembly.
4.
The above instructions and description apply to a temperature sensor compatible with
Qubino products only.
NOTE: When Qubino is wired to 110-230VAC (high voltage) the temperature sensor must
not be in direct contact with water.
Summary of Contents for Flush 2 relay
Page 17: ...EN 17 4 Package Contents Flush 2 Relay Device Installation Manual...
Page 24: ...EN 24 After Qubino installation...
Page 25: ...EN 25 3 WAY INSTALLATION WITH 2 SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...
Page 26: ...EN 26 After Qubino installation when power line and load line are in the same switch box...
Page 27: ...EN 27 After Qubino installation when power line and load line are in different switch boxes...
Page 28: ...EN 28 Before Qubino installation Where there is no neutral line N in switch box...
Page 29: ...EN 29 After Qubino installation Where there is no neutral line N in switch box...
Page 36: ...EN 36 Step 5 Turn the fuse on Step 6 Re include the device to your network...
Page 37: ...EN 37 Step 7 Start using the temperature sensor in connection with your device...