EN
.
49
Parameter no. 43
–
Watt Power Consumption Reporting Time Threshold for Q2 Load
Set value refers to the time interval with which power consumption in Watts is reported (0
–
32535 seconds). If 300 is entered by default, energy consumption report will be sent to the
gateway (hub) every 300 seconds (5 minutes).
Values (size is 2 byte dec):
•
default value 300
•
0 - Power consumption reporting disabled
•
1 - 32535 = 1 - 32535 seconds. Power consumption reporting enabled. Report is sent
according to time interval (value) set here.
Parameter no. 63
–
Choose Normally Closed or Normally Open as Default for Q1 Load
Set value determines the type of the device connected to the Q1 output. The device type can
be normally open (NO) or normally closed (NC).
Values (size is 1 byte dec):
•
default value 0
•
0 - When switch/device is off the output is 0V (NC).
•
1 - When switch/device is off the output is 230V (NO).
Summary of Contents for Flush 2 relay
Page 17: ...EN 17 4 Package Contents Flush 2 Relay Device Installation Manual...
Page 24: ...EN 24 After Qubino installation...
Page 25: ...EN 25 3 WAY INSTALLATION WITH 2 SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...
Page 26: ...EN 26 After Qubino installation when power line and load line are in the same switch box...
Page 27: ...EN 27 After Qubino installation when power line and load line are in different switch boxes...
Page 28: ...EN 28 Before Qubino installation Where there is no neutral line N in switch box...
Page 29: ...EN 29 After Qubino installation Where there is no neutral line N in switch box...
Page 36: ...EN 36 Step 5 Turn the fuse on Step 6 Re include the device to your network...
Page 37: ...EN 37 Step 7 Start using the temperature sensor in connection with your device...