9. Z-Wave Exclusion
Z-WAVE EXCLUSION
1. Connect the module to the power supply
2. Make sure the module is within direct range of your Z-Wave controller or use a hand-held Z-
Wave remote to perform exclusion
3. Enable exclusion mode on your Z-Wave controller
4. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
OR
Press and hold the S (Service) button for 2 to 6 seconds
5. The module will be excluded from your network but any custom configuration parameters
will not be erased.
FACTORY RESET
1. Connect the module to the power supply
2. Within the first minute the module is connected to the power supply, toggle the switch
connected to the I1 terminal 5 times within 3 seconds
OR
Press and hold the S (Service) button for at least 6 seconds
By resetting the module, all custom parameters previously set on the module will return to
their default values, and the owner ID will be deleted. Use this reset procedure only when the
main controller is missing or otherwise inoperable.
ⓘ
By resetting the module, all custom parameters previously set on the module will return
to their default values, and the owner ID will be deleted. Use this reset procedure only when