EN
.
10. Associations
Use associations for direct communication between the Flush Shutter module and other
devices within your Z-Wave network without the need to use the primary controller.
Association Groups:
Root device:
•
Group 1: Lifeline group (reserved for communication with the primary controller), 1 node
allowed.
•
Group 2: Basic on/off (status change report for I1 input) up to 16 nodes.
•
Group 3: Basic on/off (status change report for I2 input) up to 16 nodes.
•
Group 4: Basic on/off (status change report for sensing roller moving: up=FF, down=0)
up to 16 nodes.
•
Group 5: Basic on/off (status change report at reaching roller position: bottom=FF,
top=0) up to 16 nodes.
•
Group 6: Basic on/off (status change report at reaching roller position: bottom=FF, not
bottom=0) up to 16 nodes
•
Group 7: Multilevel set (status change report for Flush Shutter DC position), up to 16
nodes.
•
Group 8: Multilevel set (triggered at changes of value of slats tilting position) up to 16
nodes.
•
Group 9: Multilevel sensor report (triggered at change of temperature sensor) up to 16
nodes.
End point 1:
•
Group 1: Lifeline group, 0 nodes allowed.
•
Group 2: Basic on/off (status change report for I1 input), up to 16 nodes.
•
Group 3: Basic on/off (status change report for I2 input), up to 16 nodes.
•
Group 4: Basic on/off (triggered at sensing moving direction of roller: up=FF, down=0)
up to 16 nodes.
•
Group 5: Basic on/off (triggered at reaching roller position: bottom=FF, top=0) up to 16
nodes.
•
Group 6: Basic on/off (triggered at reaching roller position: bottom=FF, not bottom=0)
up to 16 nodes.
•
Group 7: Multilevel set (triggered at changes of value of the Flush Shutter DC position)
up to 16 nodes.
End point 2:
•
Group 1: Lifeline group, 0 nodes allowed.