2) Set parameter 71 to 1 ‘Venetian blinds’.
3) Exclude the module (without reset!).
4) Include the module.
5) After module inclusion beside main Shutter widget, another widget for slates control will
appear on UI.
6) By default full turn movement is set to 1.5s. If this time is too long (if after slates full cycle
Shutter starts moving up or down), decrease this time defined with parameter 72. If this time
is to short (if slats will not turn for a full cycle), increase this time defined with parameter 72.
Manual operation for Shutter
(par. 71 set to 0)
The user can connect a push-button (mono-stable) or a switch (bi-stable) to I1 and I2
terminals.
Pressing the push-button for less than 2 seconds, which is connected to I1 (up), initiates up
movement.
Pressing the push-button for less than 2 seconds, which is connected to I2 (down), initiates
down movement.
If the Shutter is moving, any press (of any push-button) will stop the movement.
Keeping the push-button, connected to I1 (up), pressed for more than 2 seconds initiates up
movement, until the push-button is released.
Keeping the push-button, connected to I2 (down), pressed for more than 2 seconds, initiates
down movement, until the push-button is released.
Manual operation for venetian blinds
(par. 71 set to 1)
Slates on start position - 0 degree
Clicking the push-button (for time < full turn slates time-par.72) connected to I1 (up), initiates
slates turning towards end - 180 degree position, until push-button is released.
Clicking the push-button (for time < full turn slates time-par.72) connected to I2 (down),
initiates Shutter down movement.
If the Shutter is moving, any click (of any push-button), will stop the movement.
Keeping the push-button pressed (for time > full turn slates time-par.72) connected to I1 (up),
initiates full slates turn and up movement, until the push-button is released.