EN
.
Parameter no. 40 – Watt Power Consumption Reporting Threshold for Q1 Load
Choose by how much power consumption needs to increase or decrease to be reported. Values
correspond to percentages so if 10 is set (by default), the module will report any power
consumption changes of 10% or more compared to the last reading.
Values (size is 1 byte dec):default value 10
•
0 - Power consumption reporting disabled
•
1 - 100 = 1% - 100% Power consumption reporting enabled. New value is reported only
when Wattage in real time changes by more than the percentage value set in this
parameter compared to the previous Wattage reading, starting at 1% (the lowest value
possible).
NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported,
REGARDLESS of percentage set in this parameter.
Parameter no. 42 – Power reporting in Watts by time interval for Q1 or Q2
The set value refers to the time interval with which the power consumption in Watts is
reported (0 – 32767 seconds). If 0 is entered (by default), energy consumption reports will not
be sent to the controller.
Values (data type is 2 byte dec):
•
default value 0 = reporting disabled
•
0 - reporting disabled
•
1 - 32767 = 1 second - 32767 seconds. Reporting enabled, power report is send
with time interval set by entered value.