6. Compatibility with Z-Wave Gateways (hubs)
Please check compatibility with your Z-Wave gateway (hub) before you purchase this device. The
compatibility table is available online.
7. Installation
Before installing the device, please read the following carefully and follow the instructions
exactly:
ⓘ
Danger of electrocution!
Installation of this device requires a great degree of skill and may be performed only by a licensed
and qualified electrician. Please keep in mind that even when the device is turned off, voltage
may still be present in the device
’s terminals.
ⓘ
Note!
Do not connect the device to loads exceeding the recommended values. Connect the device
exactly as shown in the provided diagrams. Improper wiring may be dangerous and result in
equipment damage.
Electrical installation must be protected by directly associated overcurrent protection fuse 4 A,
gG or Time lag T, rated breaking capacity 1500 A (ESKA 522.723) must be used according to
wiring diagram to achieve appropriate overload protection of the device
.
The fuse must be
installed in fuse holder type: Adele contact 503Si/1 DS according to the standard
IEC60669-2-1.
Summary of Contents for Flush Shutter
Page 3: ...EN 3 18 Warning 64 19 Regulations 64 ...
Page 19: ...EN 19 4 Package Contents Flush Shutter Device Installation Manual ...
Page 21: ...EN 21 ...
Page 25: ...EN 25 After Qubino installation ...
Page 31: ...EN 31 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below ...
Page 32: ...EN 32 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on ...
Page 33: ...EN 33 Step 6 Re include the device to your network ...
Page 34: ...EN 34 Step 7 Start using the temperature sensor in connection with your device ...