12. Associations
Use associations for direct communication between the Flush Shutter and other devices within
your Z-Wave network without the need of your primary gateway (hub).
Description:
Turn ON = Shutter move UP = move to 100%
Turn OFF = Shutter move DOWN = move to 0%
Association Groups:
Root device:
•
Group 1: Lifeline group (reserved for communication with the primary gateway (hub)), 1
node allowed.
•
Group 2: Basic on/off (Triggered at change of input I1) up to 16 nodes.
In case parameter 1 is set to on/off toggle, when switch wired to input I1 is pressed Flush
Shutter will send Basic set ON command to associated device and this device will turn ON,
when it is released Flush shutter sends Basic set OFF command to associated device and
this device will turn OFF. In case parameter 1 is set to pushbutton, when switch wired to
input I1 is pressed shutter will send Basic set ON command to associated device and this
device will turn On, when input I1 is pressed again Flush shutter sends Basic set OFF
command to associated device and this device will turn OFF.
•
Group 3: Basic on/off (Triggered at change of input I2) up to 16 nodes.
In case parameter 1 is set to on/off toggle, when switch wired to input I2 is pressed Flush
Shutter will send Basic set ON command to associated device and this device will turn ON,
when it is released Flush shutter sends Basic set OFF command to associated device and
this device will turn OFF. In case parameter 1 is set to pushbutton, when switch wired to
input I2 is pressed shutter will send Basic set ON command to associated device and this
device will turn On, when input I2 is pressed again Flush shutter sends Basic set OFF
command to associated device and this device will turn OFF.
•
Group 4: Basic on/off (Triggered at sensing moving direction of roller: up= FF, down = 00)
up to 16 nodes.
When blinds are moving up, Flush Shutter will send Basic set ON command to associated
device and associated device will turn ON. When blinds are moving down, Flush Shutter
will send Basic set OFF command to associated device and the device will turn OFF.
Summary of Contents for Flush Shutter
Page 3: ...EN 3 18 Warning 64 19 Regulations 64 ...
Page 19: ...EN 19 4 Package Contents Flush Shutter Device Installation Manual ...
Page 21: ...EN 21 ...
Page 25: ...EN 25 After Qubino installation ...
Page 31: ...EN 31 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below ...
Page 32: ...EN 32 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on ...
Page 33: ...EN 33 Step 6 Re include the device to your network ...
Page 34: ...EN 34 Step 7 Start using the temperature sensor in connection with your device ...