Flush shutter will set Switch multilevel command to associated device, the command is
actual position of blinds so the associated device will turn on same level as blinds are.
Example with association between Flush Shutter and dimmer, when shutters blinds reach
middle position 50 % it will send switch multilevel set 50 % command and dimmer will
turn on 50 %.
End point 2:
•
Group 1: Lifeline group, 0 nodes allowed.
•
Group 2: Multilevel set (Triggered at changes of value of slats tilting position), up to 16
nodes. Flush Shutter device will send Switch multilevel set command to associated
device, the command is actual position of tilts.
Example with association between Flush shutter and dimmer
When shutters tilts rotate to middle position 50 % it will send switch multilevel set 50 %
command and dimmer will turn on 50 %.
End point 3 (External Temperature Sensor):
•
Group 1: Lifeline group, 0 nodes allowed.
•
Group 2: Multilevel sensor report (triggered at sensed different value
–
sensor sold
separately), up to 16 nodes. Flush Shutter device will send Multilevel sensor report to
associated device, this will send the information of actual temperature that was
measured with temperature sensor.
Summary of Contents for Flush Shutter
Page 3: ...EN 3 18 Warning 64 19 Regulations 64 ...
Page 19: ...EN 19 4 Package Contents Flush Shutter Device Installation Manual ...
Page 21: ...EN 21 ...
Page 25: ...EN 25 After Qubino installation ...
Page 31: ...EN 31 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below ...
Page 32: ...EN 32 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on ...
Page 33: ...EN 33 Step 6 Re include the device to your network ...
Page 34: ...EN 34 Step 7 Start using the temperature sensor in connection with your device ...