EN
.
50
NOTE1: After the value of this parameter is changed, first exclude device (without setting
parameters to their default values), wait at least 30s and then re-include the device!
Parameter no. 72
–
Slats tilting full turn time
Set the time, required by the slats, to make a full turn (180 degrees).
Values (size is 2-byte dec):
•
default value 150 = 1.5 seconds
•
0 - tilting time disabled
•
1 - 32767 = 0.01seconds
–
327.67 seconds
NOTE: If the set time is too long and a full turn was already performed, the device will start to
move up or down for the remaining time.
Parameter no. 73
–
Slats position
This parameter is used to enable/disable the slats to return to the previously set position after
being activated via the Z-Wave gateway(hub), push-button operation or when the lower limit
switch is reached.
Summary of Contents for Flush Shutter
Page 3: ...EN 3 18 Warning 64 19 Regulations 64 ...
Page 19: ...EN 19 4 Package Contents Flush Shutter Device Installation Manual ...
Page 21: ...EN 21 ...
Page 25: ...EN 25 After Qubino installation ...
Page 31: ...EN 31 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below ...
Page 32: ...EN 32 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on ...
Page 33: ...EN 33 Step 6 Re include the device to your network ...
Page 34: ...EN 34 Step 7 Start using the temperature sensor in connection with your device ...