Parameter no. 120
–
Temperature Sensor Reporting Threshold
If an external digital temperature sensor (sold separately) is connected to the device, it reports
temperature readings based on the threshold defined in this parameter. This parameter only
applies to the Celsius temperature unit (the Fahrenheit unit is currently not supported).
Values (size is 1-byte dec):
•
Default value 5 = 0.5
°C
•
0
–
Reporting disabled
•
1 - 127 = Where 1 stands for 0.1
°C
and 127 stands for 12.7
°C.
15. Technical Specifications
Power supply/
Alimentation électrique/
Netzspannung/
Strömförsörjning
110 - 240 Vac
±10
%
50/60 Hz, (24-30 VDC*)
Rated load current (resistive load) * /
Courant nominal (charge résistive)*/
Nennstromstärke (ohmsche Last)*/
Nominell lastström (resistiv
last)*
2 X 4 A (240 Vac) /
2 X 4 A (110 Vac) /
Output circuit power , (resistive load)/
Puissance du circuit ,
(charge résistive)/
2 X 960 W (240 Vac) /