EN
.
38
10. Adding the device to a Z-Wave network (Inclusion)
AUTOMATICALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (AUTO INCLUSION)
1. Enable add/remove mode on your Z-Wave gateway (hub)
2. Automatic selection of secure/unsecure inclusion
3. Connect the device to the power supply (with the temperature sensor already connected
–
sold separately*).
4. Auto-inclusion will be initiated within 5 seconds of connection to the power supply and the
device will automatically enrol in your network
NOTE: the device can be automatically added to a Z-Wave network during the first 2 minutes
after connected to the power supply.
MANUALLY ADDING THE DEVICE TO A Z-WAVE NETWORK (MANUAL INCLUSION)
1. Enable add/remove mode on your Z-Wave gateway (hub)
2. Connect the device to the power supply (with the temperature sensor already connected*)
3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds. The device has to
get On/Off signal 3 times, meaning 3 times push of the button or with the normal button 3
times On/Off. Perform this operation slowly, waiting more than 0,5s between pushes.
OR
If the device is powered by 24 VDC SELV supply, press and hold the S (Service) button for max 2
seconds
4. A new multi-level device will appear on your dashboard
5. Inclusion with the switch connected to I1 terminal is not limited by time
*If connecting the temperature sensor, switch off the power supply and make sure the device is
excluded from your network BEFORE connecting the sensor.
ⓘ
Make sure the device is excluded from your network before connecting the temperature
sensor. Switch off the power supply, connect the temperature sensor, and re-include the device
to your network.
Summary of Contents for Flush Shutter
Page 3: ...EN 3 18 Warning 64 19 Regulations 64 ...
Page 19: ...EN 19 4 Package Contents Flush Shutter Device Installation Manual ...
Page 21: ...EN 21 ...
Page 25: ...EN 25 After Qubino installation ...
Page 31: ...EN 31 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below ...
Page 32: ...EN 32 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on ...
Page 33: ...EN 33 Step 6 Re include the device to your network ...
Page 34: ...EN 34 Step 7 Start using the temperature sensor in connection with your device ...