1. Connect the R.G.B.W. Color LED Dimmer according to wiring diagram.
- First, connect RGBW strip, outputs (R,G,B,W) RGB/RGBW/LED diodes, halogen lights, or inputs (IN1~IN4).
- Second, connect the power supply.
If the device is properly connected, the RGBW strip will blink once. Note that the device must be powered by a dedicated stabilized power adapter.
2. In the status of the factory default (Not Paired), the red light and green light will blink by turns, eg. red, green, red, green, etc..
3. Include the R.G.B.W. Color LED Dimmer into the Z-wave network, press service button 3 times in 2 seconds. If the device is properly included, the green light
will remains on.
4. Exclude the Flush RGBW Dimmer into the ZWave network, press 3 times in 2 seconds. If the device is properly excluded, the green light will blink and the data
will be reset to the factory default values.
5. Please pull out the antenna and keep it at 90 degree to enhance the RF signals.
6. Support auto inclusion: Install the device, connect with the power, and the auto inclusion function will work in about 2 minutes.
7. Support remote exclusion: Through configuration setting. Please refer to the following table.
 

 
 

Summary of Contents for GOAEZMNHWD1

Page 1: ...r level of security to maintain backward compatibility For more information about Z Wave technology devices white papers etc please refer to www z wave info Product Description Qubino Flush RGBW modul...

Page 2: ...7 When the Controller is damaged or lost and you have already transferred the control function to an external control switch before the product can be normally operated In other case please purchase...

Page 3: ...green light will blink by turns eg red green red green etc 3 Include the R G B W Color LED Dimmer into the Z wave network press service button 3 times in 2 seconds If the device is properly included t...

Page 4: ...o certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command typically a...

Page 5: ...1 Byte Default Value 0 Setting Description 1 Ocean 2 Lightning 3 Rainbow 4 Snow 5 Sun Parameter 4 Auto scene duration NOTE Using this parameter it is possible to change Auto scene mode duration Size...

Page 6: ...werlevel Firmware Update Md Association Version Explanation of Z Wave specific terms Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Con...

Page 7: ...ku GOAEZMNHWD1 7 7 c 2020 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwave eu The template is maintained by Z Wave Europe GmbH The product content is main...