Parameter no. 67
–
Ignore start level
Choose whether the device should use (or disregard) the start dimming level value. If the device
is configured to use the start level, it should start the dimming process from the currently set
dimming level. This parameter is used with association group 3.
Values (size is 1 byte dec):
•
default value 0
•
0
–
use the start level value
•
1 - ignore the start level value
Parameter no. 68
–
Dimming duration
Choose the time during which the device will transition from the current value to the new
target value. This parameter applies to the association group 3.
Values (size is 1 byte dec):
•
default value 0 (dimming duration according to parameter 66)
•
1 - 127 (from 1 to 127 seconds)