EN
.
42
Parameter no. 4
–
Input IN4 configuration
Available configuration parameters (size is 1 Byte DEC)
•
Default value: = 1 (NORMAL mode
–
momentary switch type)
•
1
–
NORMAL mode
–
momentary switch type
•
2
–
NORMAL mode
–
toggle switch type
•
3
–
NORMAL mode
–
toggle with memory switch type (exp. Motion sensor)
•
4
–
BRIGHTNESS mode
–
momentary switch type
•
5
–
BRIGHTNESS mode
–
toggle switch type
•
6
–
BRIGHTNESS mode
–
toggle with memory switch type (exp. Motion sensor)
•
7 - RAINBOW mode
–
momentary switch type
•
8
–
SCENE mode
–
momentary switch type
•
9
–
SCENE mode
–
toggle switch type
•
10
–
SCENE mode
–
toggle with memory switch type (exp. Motion sensor)