EN
.
44
Parameter no. 7
–
Memorize device status at power cut
Device will be set to status memorized before power cut.
Available configuration parameters (size is 1 Byte DEC)
•
Default value 0
•
0
–
device does not memorize its status at power cut. Load is disconnected
•
1
–
device memorizes its status at the power cut. Load will be set to the status from
before power cut
Parameter no. 8
–
Automatic turning off output after set time
Output is turned automatically off after the time, set in this parameter.
Available configuration parameters (size is 2 Byte DEC)
•
Default value 0
•
0
–
Auto OFF disabled
•
1
–
32536 = 1 second
–
32536 seconds Auto OFF