GV304N User Manual
TRACGV304NUM001
- 23 -
Figure 10.
Typical Ignition Detection
IGN (Pin3)is used for ignition detection. It is strongly recommended to connect this pin to ignition
key “RUN” position as shown up.
An alternative to connecting to the ignition switch is to find a non permanent power source that is
only available when the vehicle is running. For example the power source for the FM radio.
IGN signal can be configured to start transmitting information to backend server when ignition is
on; and enter power saving mode when ignition is off.
There are three general purpose digital inputs on GV304N. They are all negative trigger.
3.9.
Digital Inputs
Table 8.
Electrical Characteristics of the digital inputs
Logical State
Electrical Characteristics
Active
0V to 0.8V
Inactive Open
The following diagram shows the recommended connection of a digital input.
QUECLINK