GV55LITE User manual
TRACGV55LITEUM001
- 13 -
Table 6.
Electrical Characteristics of Ignition Detection
Logical State
Electrical State
Active
5.0V to 32V
Inactive
0V to 3V or Open
Figure 7.
Typical Ignition Detection
IGN (Pin3) is used for ignition detection. It is strongly recommended to connect this pin to
ignition key “RUN” position as shown up.
An alternative to connecting to the ignition switch is to find a non permanent power source
that is only available when the vehicle is running. For example the power source for the
FM radio.
IGN signal can be configured to start transmitting information to backend server when
ignition is on; and enter power saving mode when ignition is off.
There are one general purpose digital inputs on GV55LITE. It is negative trigger.
Table 7.
Electrical Characteristics of the digital inputs
Logical State
Electrical Characteristics
Active
0V to 0.8V
Inactive
Open
The following diagram shows the recommended connection of a digital input.
3.5.
Ignition Detection
3.6.
Digital Inputs
Queclink
Confidential