SC200L Hardware Design
SC200L_Hardware_Design
71 / 103
7.3 Operation and Storage Temperatures
The operating temperature is listed in the following table.
Table 8: Operation and Storage Temperatures
Parameter
Min.
Typ.
Max.
Unit
Operating temperature range
1)
-30 +25 +75
ºC
Storage Temperature Range -40
+90
ºC
NOTE
1)
Within the operation temperature range, the module is 3GPP compliant.
7.4 Current Consumption
The values of current consumption are shown below.
Table 9: SC200L-CE Current Consumption
transmission slot)
USB_VBUS
4.50 5.0
9.20 V
Parameter
Description
Conditions
Min
Typ.
I
VBAT
OFF state
Power down
350
μ
A
GSM/GPRS supply
current
Sleep (USB disconnected) @DRX=2
3.5
mA
Sleep (USB disconnected) @DRX=5
3
mA
Sleep (USB disconnected) @DRX=9
3
mA
WCDMA supply
Sleep (USB disconnected) @DRX=6
4.7
mA