LTE-A Module Series
EG12 Hardware Design
EG12_Hardware_Design 31 / 97
3.4. Operating Modes
The table below summarizes different operating modes of EG12.
Table 5: Overview of Operating Modes
V
IH
min=1.2V
V
IH
max=2.0V
default.
Low level wakes up
the module.
If unused, keep it
open.
W_DISABLE#
151
DI
Airplane mode
control
V
IL
min=-0.3V
V
IL
max=0.6V
V
IH
min=1.2V
V
IH
max=2.0V
1.8V power domain.
Pulled up by
default.
In low voltage level,
the module will
enter airplane
mode.
If unused, keep it
open.
RESERVED Pins
Pin Name
Pin No.
I/O
Description
DC
Characteristics
Comment
RESERVED
4, 6~9, 11, 12,
14, 15, 18~23,
72, 91, 95,
134, 176,
192~195,
197~201,
209~213
Reserved
Keep these pins
unconnected.
Mode
Details
Normal
Operation mode
Idle
Software is active. The module has registered on the network, and it is
ready to send and receive data.
Talk/Data
Network connection is ongoing. In this mode, the power consumption is
decided by network setting and data transfer rate.
Minimum
Functionality
Mode
AT+CFUN=0
command can set the module to a minimum functionality mode without
removing the power supply. In this case, both RF function and (U)SIM card will be
invalid.