6.3. Operation and Storage Temperatures
The operation and storage temperatures are listed in the following table.
Table 41: Operation and Storage Temperatures
1.
1)
Within operating temperature range, the module is 3GPP compliant.
2.
2)
Within extended temperature range, proper mounting, heating sinks and active cooling may be
required to make certain functions of the module such as voice, SMS, data transmission, emergency
call to be realized. Only one or more parameters like Pout might reduce in their value and exceed the
specified tolerances. When the temperature returns to normal operating temperature levels, the
module will meet 3GPP specifications again.
6.4. Current Consumption
6.4.1. EG12-GT Current Consumption
Table 42: EG12-GT Current Consumption
minimum and the maximum
values.
USB_VBUS
USB connection
detection
3.3
5.0
5.25
V
Parameter
Min.
Typ.
Max.
Unit
Operation Temperature Range
1)
-30
+25
+75
ºC
Extended Operation Range
2)
-40
+85
ºC
Storage temperature range
-40
+90
ºC
Parameter Description
Conditions
Typ.
Unit
I
VBAT
OFF state
Power down
20
uA
I
VBAT
Sleep state
AT+CFUN=0
(USB disconnected)
0.98
mA
NOTES