background image

GL200 User manual

TRACGL200UM001

- 9 -

4.3. Install SIM Card

z

First, open the cover of SIM card..

z

Then insert the SIM card into the slot of SIM card according to the direction shown.

z

Finally, cover the slot.

4.4. Turn on/Turn off

z

Turn on:

‹

Method 1: Press the Power key at least 3 seconds and release it to turn on GL200. At

the same time,

PWR LED

will light on.

‹

Method 2: Connect device to charger or external battery, and it will turn on

automatically,

PWR LED

will light on.

z

Turn off:

‹

Method 1: Press the power key at least 3 seconds; PWR LED will Fast flash and then

turn off, it indicates that GL200 is turned off. It is only valid to turn off when using

internal battery. Please note the end-user can not power off GL200 when the power key

is disabled by protocol.

‹

Method 2: If using external battery, device will power turn-off when external battery

disconnect.

Summary of Contents for gl200

Page 1: ...GPS Locator GL200 User Manual TRACGL200UM001 Revision 1 01 ...

Page 2: ...n Furthermore system validation of this product designed by Queclink within a larger electronic system remains the responsibility of the customer or the customer s system integrator All specifications supplied herein are subject to change Copyright This document contains proprietary technical information which is the property of Queclink Limited copying of this document and giving it to others and...

Page 3: ...riple Color LEDs Description 6 2 4 External Power Interface 6 2 4 1 External DC Charger Interface 6 2 4 2 External Battery Interface 7 2 5 External GPS antenna specification 7 2 6 Ignition Detection 8 3 Getting Started 9 3 1 Parts List 9 3 2 Battery Charging 9 3 3 Install SIM Card 10 3 4 Turn on Turn off 10 4 Troubleshooting and Safety info 11 4 1 Troubleshooting 11 4 2 Safety info 11 ...

Page 4: ...GL200 User manual TRACGL200UM001 3 0 Revision history Revision Date Author Description of change 1 01 2010 08 03 Ella HUANG Initial ...

Page 5: ...protocol GL200 can communicate with the backend server through GPRS GSM network and transfer reports of emergency Geo fencing device status and scheduled GPS position etc Service provider is easy to setup their tracking platform based on the functional Track protocol This device complies with part 22 and part 24 of the FCC rules Operation is subject to the following two conditions 1 this device ma...

Page 6: ...nterfaces Mini USB Connector Include external power and UART Power Button For power on and power off Can be disabled by the air interface protocol Function Button For SOS alarm or quick setting of Geo Fence Gerneral Specifications Dimension 67 5mm 40mm 21mm Weight 60g Backup Battery Li Polymer 1300 mAh 3 7V Standby TIme Without reporting 300 to 400 Hours 5 minutes reporting 100 to 150 Hours 10 min...

Page 7: ...ive SOS alarm Mini USB interface z Connect a 5V DC adapter can power GL200 and charge the internal battery z Connnet a 3 7V Li ion or Li Polymer battery can power GL200 z Backend server developer or administrator can use the Data_Cable_M to configure GL200 3 2 Two Triple Color LEDs Description There are three LED in GL200 the description as following Light Event State GPS LED If LED On is not sele...

Page 8: ...rging Fast flash Device is in process of turn off Device is in abnormal status Charger connects and charging has completed Ever light Device is working in normal status GSM LED Network searching Fast flash SIM pin locked Network has been registered Slow flash Power off Closed ...

Page 9: ...very list of GL200 4 2 Battery Charging z Please connect AC DC power adapter with GL200 z Insert the AC DC power adapter into the power socket z During charging the PWR LED is flashing fast When the battery is full charged the PWR LED will be Ever light z You can also charge the battery by USB cable which connects GL200 with the PC z Charging time is about 5 hours Note Before the first time using ...

Page 10: ...me time PWR LED will light on Method 2 Connect device to charger or external battery and it will turn on automatically PWR LED will light on z Turn off Method 1 Press the power key at least 3 seconds PWR LED will Fast flash and then turn off it indicates that GL200 is turned off It is only valid to turn off when using internal battery Please note the end user can not power off GL200 when the power...

Page 11: ...ddress for the backend server is an identified address in the internet Unable to power off GL200 The function of power key was disabled by AT GTSFR Enable the function of power key by AT GTFKS Unable to power off GL200 if charger connected or using external battery Disconnect charger or external and try again No response from UART when configure GL200 through UART GL200 is in power saving mode Rem...

Page 12: ...rature will damage the device or even cause the battery explosion z Please do not use GL200 on the airplane or near medical equipment Queclink Wireless Solutions Room 501 Building 9 No 99 Tianzhou Road Shanghai China 200233 Tel 86 21 51082965 Fax 86 21 54451990 ...

Reviews: