L10 Hardware Design
V
IL
<0.5V
V
IH
>2.1V
Pulldown > 1ms
VCC
RESET_N
(INPUT)
Figure
4:
Timing of restart system
3.4.2 Turn off
Shutting down the module's power supply is the only way to turn off the system. For more details of this
part application, please refer to document [1].
3.5 Power saving
3.5.1 Enter standby mode
The EXTINT0 pin can be used to drive the module into standby mode. When the EXTINT0 pin is
changed from high to low, the module will enter the standby mode. In this case, the UART port and the
USB port are not accessible, and the current consumption of the module is also minimal.
Note: When USB interface of the module is being used, the module could not enter standby mode.
3.5.2 Exit from standby mode
When the EXTINT0 pin is changed from low to high, the module will exit from the standby mode.
3.6 RTC backup
The RTC (Real Time Clock) power supply of module can be directly provided by an external capacitor
or battery (rechargeable or non-chargeable) through the V_BCKP pin. It can supply power for
L10_HD_V1.01
- 16 -
Quectel
Confidential