Smart Module Series
SC690A_Series_Hardware_Design 94 / 105
6.5. ESD
If the static electricity generated by various ways discharges to the module, the module maybe damaged
to a certain extent. Thus, please take proper ESD countermeasures and handling methods. For example,
wearing anti-static gloves during the development, production, assembly and testing of the module;
adding ESD protective component to the ESD sensitive interfaces and points in the product design of the
module.
Table 52: Electrostatics Discharge Characteristics (25 °C, 45 % Relative Humidity)
6.6. Operating and Storage Temperatures
Table 53: Operating and Storage Temperatures
2
Within operating temperature range, the module is 3GPP compliant.
V
IL
Input low voltage
-0.3
0.59
V
V
OH
Output high voltage
2.36
2.95
V
V
OL
Output low voltage
0
0.4
V
Tested Interfaces
Contact Discharge
Air Discharge
Unit
VBAT, GND
±5
±10
kV
All Antenna Interfaces
±5
±10
kV
Other Interfaces
±0.25
-
kV
Parameter
Min.
Typ.
Max.
Unit
Operating Temperature Range
2
-35
+25
+75
°C
Storage temperature range
-40
-
+90
°C