5.1 ELECTRICAL REQUIREMENTS
The Quest 100 dehumidifier plugs into a common grounded 115VAC outlet. The dehumidifier draws
5.0 Amps at 80 F and 60% RH. Locate the dehumidifier in an area where the cord’s length (9’) easily
reaches a 115 VAC electrical outlet with a minimum of 15 Amp circuit capacity. If used in an area that
may become wet, a GFCI protected circuit is recommended. The unit should not be used in areas
prone to flooding. Consult local electrical codes for any further information.
An optional remote dehumidistat is available for use with the Quest 100 dehumidifier and is to be
located remotely from the dehumidifier.
CAUTION!
ELECTRICAL SHOCK HAZARD
: Electrical power must be present to
perform some tests. These tests should be performed by a qualified service person.
WIRING SCHEMATIC
P/N 4042336 Rev. B
BLK-1
SERIAL
SWITCH
PRESSURE
SWITCH
BL
U-14
BL
U-15
( )
( )
DISPLAY BOARD
(CL
ASS
2)
(CL
ASS
2)
(CLASS 2)
(CLASS 2)
(CLASS 2)
Summary of Contents for 100