1-877-420-1330
Quest 150 Dual
Installation, Operation and Maintenance Instructions
5
www.QuestClimate.com
info@QuestClimatecom
4. Installation
CAUTION! Remove compressor shipping tie from the unit. Failure to remove shipping tie will
cause excess vibration to be transmitted to the frame.
4.1 Remove Compressor Shipping Support
The Quest 150 Dual uses a compressor to power the refrigeration system. To protect the compressor
and refrigeration system during shipping a plastic tie wrap secures it to the units frame. Remove the
tie wrap by cutting the tie wrap and pulling from the unit as shown. After removing tie wrap, insert
plastic plugs provided into the holes.
4.2 Location
The Quest 150 Dual can be installed in a variety of locations to meet the owner’s needs; other considerations include:
1. Providing access to a 115 VAC power outlet (10’ power cord is provided).
2. Locating near a floor or other suitable drain.
3. Mount at least 4” above drain. (P-trap recommended - See pg. 8)
4. Do not install the Quest 110 Dual with the exhaust of the unit within 1’ of a wall or obstruction. Do not place the unit
near open water.
5. Duct work not recommended for gardening (DO NOT duct heat out).
6. Hanging not required - Floor install is ok.
4.2A How to hang dehumidifier
A. Attach brackets (PN 4036568) with feet. Tighten with 5/8” wrench.
B. Attach chain or SunGrip to bracket. Ensure materials have adequate weight rating.
Figure 1: Recommended install shown
A
B
B
A
A
A
A
A
B
B
P-trap
(see section 4.5 for more info)
Bottom view
of unit and
bracket
Bracket
(4036568)
note: plumb
condensate water
to drain or
reclamation
reservoir