3.3 Air Ducting 

3.3A Inlet Ducting 

Occasionally the area to be filtered is difficult to access and/or the unit cannot be located in the area. In such cases, the 

air can be ducted to the unit’s inlet.

A round 16” diameter flexible duct can be attached to the unit inlet. It connects by placing the wire in the duct over the 

duct collar lip at one location and working over it over the lip gradually. It may be removed after use for easier transport 

and storage. Flexible 16” duct is available from Therma-Stor LLC. (4028357)

3.3B Oulet Ducting 

A detachable trapazoid shaped exhaust ring is supplied that will allow 10” round lay-flat plastic duct to be attached to the 

Quest H5 HEPA System outlet. Lay-flat plastic ducting is available from Therma-Stor LLC. (4024935)

To attach ducting to the collar, remove the ring from the unit by pressing release tab at the top of the grill. Put the plastic 

duct end through the inside of the ring. Roll the duct end outward so that it over-laps the outside of the ring. Clip the 

ring back onto the exhaust grill.

3.3C Negative Air Ducting 

The Quest H5 HEPA System can be used to filter and exhaust air from a space. When exhausting to outside the space, 

the space will be under a slight negative pressure. This will help prevent airborne particles from leaving the space, because 

the negative pressure will draw air in through openings in the space’s exterior surfaces.

CAUTION: Exhausting too much air from a space with open combustion devices (e.g. furnace, fireplace or water 

heater) can cause those devices to backdraft. This can contaminate the space with potentially fatal gases.

In such cases, the Quest H5 HEPA System must be used in one of the following three ways:

A.  As a filtering unit only. Exhausting no air from the space and thus causing no negative pressure or backdrafting.

B.  Exhausting a very limited amount of air which does not cause backdrafting. In case B, the open combustion devices 

must be thoroughly checked to guarantee that they do not backdraft while the Quest H5 HEPA System is running.

C.  Direct the outlet duct from the H5 HEPA System to the room with the open combustion device(s). This will 

positively pressurize the room with HEPA filtered air, thus preventing backdrafting. As in case B, those combustion 

devices must be checked after the H5 HEPA System is running to guarantee that they are not backdrafting.

3.4 Power/Speed Control 

The power/speed switch is located on the control panel. When turned on to any speed, it powers the impeller fan.

Occasionally the impeller fan may not start on low speed. If this occurs, rotate the speed control to high speed until the 

impeller fan starts, then adjust it to a lower speed.

CAUTION: Do not remove HEPA filter with the unit on. Removing the top and filters while running will expose the 
dangerous rotating impeller fan. Disconnect the appliance before changing filters.

3.5 Resettable Circuit Breaker

The 12 AMP thermal response resettable circuit breaker protects the unit and devices connected to its duplex GFCI 

outlet.
The circuit breaker is designed to sense the total current draw through the circuit. The circuit breaker “trips” when more 

than 12 amps of electrical current are drawn through the device’s power cord. Should an over-current condition occur, 

the H5 on-board circuit breaker prevents nuisance visits to a remote power junction box.

Summary of Contents for 4031450

Page 1: ...tested engineering principles and has passed a thorough inspection for quality of workmanship and function Installation Operation and Maintenance Instructions Read and Save These Instructions 1 Quest H5 Compact design Variable speed flow Multiple ducting options Tough plastic cabinet Optional carbon filter TS 986 02 20 Rev B Patent Pending 4201 Lien Rd Phone 608 237 8400 Madison WI 53704 Toll Free...

Page 2: ...utlet Ducting 3 3 3C Negative Air Ducting 3 3 4 Power Speed Control 3 3 5 Resettable Circuit Breaker 4 3 6 GFCI Protection and On Board Duplex VAC Outlet 4 3 7 Servicing 4 4 Maintenance 4 4 1 Air Filters 4 4 2 Filter Replacement 4 4 2A Filter change light 4 4 2B Optional Activated Carbon Potassium Permanganate filters 5 5 Service 5 5 1 Warranty 5 6 Wiring Diagram 6 7 Service Parts 7 Warranty 9 Ser...

Page 3: ...let One foot minimum distance to obstructions Indoor use only Do not use as stool or bench Do not operate with damaged cord or plug Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over 3 Operation 3 1 Transporting the Quest H5 The H5 sh...

Page 4: ...can cause those devices to backdraft This can contaminate the space with potentially fatal gases In such cases the Quest H5 HEPA System must be used in one of the following three ways A As a filtering unit only Exhausting no air from the space and thus causing no negative pressure or backdrafting B Exhausting a very limited amount of air which does not cause backdrafting In case B the open combust...

Page 5: ...FCI When the Quest H5 is first turned on check for excessive vibration If the unit vibrates excessively or if impeller rubs on housing turn off the unit immediately Have a service technician inspect the unit to locate the problem 4 Maintenance Use extreme caution when changing the HEPA filter as hazardous material could be trapped in the media Always make sure to dispose of filters in the appropri...

Page 6: ...ey use a blend of activated carbon and potassium permanganate This blend removes the vast majority of gaseous contaminants encountered in most filtering applications The activated carbon removes the heavier volatile organics while the potassium permanganate removes lower molecular weight contaminants This is well suited to the smoke odors present after fire damage The life of the media blend depen...

Page 7: ...ller Fan Speed Control 6 4032143 Impeller Fan Speed Control Knob 7 4037569 Cord 14ga 25 8 4033031 08 Run Capacitor 20 mfd 370 VAC 9 4031861 10 Lay flat duct collar ring Optional Parts Item Part No Description 4031878 Air Filter Disposable Carbon Potassium Permanganate 4028357 Duct Flex 16 x 25 4024935 Duct Lay Flat 10 x 250 HOT NEUTRAL BREAKER WHT BLK LOAD LINE GROUNDED GFCI DUPLEX PLUG 12 AMP CIR...

Page 8: ...Quest H5 Installation Operation and Maintenance Instructions 8 1 877 420 1330 www QuestClimate com info QuestClimate com ...

Page 9: ...ther cause beyond Therma Stor LLC s reasonable control If any Quest H5 part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Quest H5 with FOCUS Technology is out of service while awaiting covered warranty service Warranty service will be performed during normal working hours...

Reviews: