6. Wiring Diagram

 

7. Service Parts

Item  

Part No. 

Description

1  

4031877 

Air Filter, Pleated, 1” x 18” x 18”

4031864 

Air Filter, HEPA, 2.5” x 18” x 18” (99.97% Efficient)

4031863 

HEPA filter hold down clip

4035832 

Impeller Fan

4032854 

Impeller Fan Speed Control

4032143 

Impeller Fan Speed Control Knob

4037569 

Cord (14ga, 25’)

4033031-08 

Run Capacitor, 20 mfd, 370 VAC

4031861 

10” Lay flat duct collar ring

Optional Parts 
Item  

Part No. 

Description

4031878 

Air Filter, Disposable Carbon/Potassium Permanganate

4028357 

Duct, Flex, 16” x 25’

4024935 

Duct, Lay Flat, 10” x 250’

HO

T

NEUTR

AL

BREAKER

WHT

BLK

LOAD

LINE

GROUNDED

GFCI

DUPLEX

PLUG

12 AMP

CIRCUIT

BLK

WHT

BLU

BLK

BRN

PUR

GR

Y

OR

G

BL

U

AIR 

PRESSURE 

SWITCH

FILTER 

CHECK 

LIGHT

TRIAC

BLOWER 

SPEED 

CNTRL

20 

μ

F

CAPACITOR

WHT

BLK

120v 60Hz 

single phase

Summary of Contents for 4031450

Page 1: ...tested engineering principles and has passed a thorough inspection for quality of workmanship and function Installation Operation and Maintenance Instructions Read and Save These Instructions 1 Quest H5 Compact design Variable speed flow Multiple ducting options Tough plastic cabinet Optional carbon filter TS 986 02 20 Rev B Patent Pending 4201 Lien Rd Phone 608 237 8400 Madison WI 53704 Toll Free...

Page 2: ...utlet Ducting 3 3 3C Negative Air Ducting 3 3 4 Power Speed Control 3 3 5 Resettable Circuit Breaker 4 3 6 GFCI Protection and On Board Duplex VAC Outlet 4 3 7 Servicing 4 4 Maintenance 4 4 1 Air Filters 4 4 2 Filter Replacement 4 4 2A Filter change light 4 4 2B Optional Activated Carbon Potassium Permanganate filters 5 5 Service 5 5 1 Warranty 5 6 Wiring Diagram 6 7 Service Parts 7 Warranty 9 Ser...

Page 3: ...let One foot minimum distance to obstructions Indoor use only Do not use as stool or bench Do not operate with damaged cord or plug Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over 3 Operation 3 1 Transporting the Quest H5 The H5 sh...

Page 4: ...can cause those devices to backdraft This can contaminate the space with potentially fatal gases In such cases the Quest H5 HEPA System must be used in one of the following three ways A As a filtering unit only Exhausting no air from the space and thus causing no negative pressure or backdrafting B Exhausting a very limited amount of air which does not cause backdrafting In case B the open combust...

Page 5: ...FCI When the Quest H5 is first turned on check for excessive vibration If the unit vibrates excessively or if impeller rubs on housing turn off the unit immediately Have a service technician inspect the unit to locate the problem 4 Maintenance Use extreme caution when changing the HEPA filter as hazardous material could be trapped in the media Always make sure to dispose of filters in the appropri...

Page 6: ...ey use a blend of activated carbon and potassium permanganate This blend removes the vast majority of gaseous contaminants encountered in most filtering applications The activated carbon removes the heavier volatile organics while the potassium permanganate removes lower molecular weight contaminants This is well suited to the smoke odors present after fire damage The life of the media blend depen...

Page 7: ...ller Fan Speed Control 6 4032143 Impeller Fan Speed Control Knob 7 4037569 Cord 14ga 25 8 4033031 08 Run Capacitor 20 mfd 370 VAC 9 4031861 10 Lay flat duct collar ring Optional Parts Item Part No Description 4031878 Air Filter Disposable Carbon Potassium Permanganate 4028357 Duct Flex 16 x 25 4024935 Duct Lay Flat 10 x 250 HOT NEUTRAL BREAKER WHT BLK LOAD LINE GROUNDED GFCI DUPLEX PLUG 12 AMP CIR...

Page 8: ...Quest H5 Installation Operation and Maintenance Instructions 8 1 877 420 1330 www QuestClimate com info QuestClimate com ...

Page 9: ...ther cause beyond Therma Stor LLC s reasonable control If any Quest H5 part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Quest H5 with FOCUS Technology is out of service while awaiting covered warranty service Warranty service will be performed during normal working hours...