13

QUEST 506 

 

                                                   INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

QUESTCLIMATE.COM

(877) 420-1330

SERVICE PARTS LIST

Item  Part No 

 

Description

  1 

4029507 

 

CONTROL,HIGH PRESSURE

  2 

4029508 

 

CONTROL,LOW PRESSURE

 3 

4029575 

  RELAY

 4 

4031101 

 

CONTACTOR

 5 

4031406 

  TRANSFORMER

 

 

(4042945)    

TRANSFORMER (277V)

  6 

4035949-06  

CAPACITOR,COMP.

 

 

(4035949-12) 

CAPACITOR,COMP. (277V)

 7 

4036164-20   TUBE,CU,CPLRY 

  8 

4036559 

 

CIRCUIT BREAKER

 9 

4039729 

  CLAMP,CAPACITOR

 10 

4037221-06   

CAPACITOR

   

(4042209-04)  CAPACITOR (277V)

 11 

4037699 

 

THERMISTOR

 12 

4039607 

 

CPRSR

 

 

(4042942)   

CPRSR (277V)

 13 

4037702 

 

FILTER,DRIER

Item  Part No 

 

Description

 14 

4037703-04    

COIL,EVAP

15  

4037704-02   

COIL,CONDENSER 

16  

4037707 

 

TXV,3  TON

 17 

4037708 

 

FAN,MOTORIZED IMPELLER

 

 

(4042941) 

 

FAN,MOTORIZED IMPELLER (277V)

 18 

4037728 

 

CORD

   

(4042899)   

CORD (277V)

 19 

4038135 

 

HANDLE,POCKET

 20 

4038136 

 

BEZEL,HANDLE

 21 

4038178 

 

WIRE  HARNESS

 22 

4038079 

 

LUG,GROUND

 23 

4038219 

 

FOOT,RUBBER,1.25”  DIA

 24 

4038225-01   

BRACKET,FOOT,RIGHT

 25 

4038226-01   

BRACKET,FOOT  LEFT

 26 

4038215 

 

BLOCK,  WIRING

 27 

4039691 

 

CONTROL  ASSY

28 

4038233 

 

FILTER (QTY 2)

 Part No 

 Qty 

Description 

 

4020175 

Controller, Humidity

4028531 

DEH 3000R Control, Remote

4041550 

Cloud Control

4041560 

Cloud Control Plus

 Part No 

 Qty 

Description 

4032220 

Kit, Pump

4038642 

Kit, Intake Duct

4038641 

Kit, Exhaust Duct

4038644 

Drain Trap Kit

OPTIONAL PARTS LIST

1

17

2

19,20

6

23

24

25

10

12

3

13

14

28

15

16

8

27

9

4

5

26

22

Summary of Contents for 506

Page 1: ...O M 87 7 420 1330 Patents thermastor com patents Serial Number Install Date Sold By T S 10 16 01 2 2 R E V J Quiet operation 230V 277V units Long life impeller Industry leading efficiency Superior MERV 13 air filtration Environmentally friendly refrigerant Auto restart after power outages ...

Page 2: ...e Water Removal 6 4 4 Hanging 6 5 Controls 7 5 1 Humidity Control 7 5 2 24VAC Wiring 7 5 2A Deh 3000R 8 5 2B Honeywell Remote Humidistat 8 5 2C Daisy Chain 8 6 Maintenance 8 6 1 Standard Air Filter 9 7 Service 9 7 1 Warranty 9 7 2 Technical Description 9 7 3 Troublshooting 9 8 Ducting Guidelines 11 Wiring Diagram 12 Service Parts List 13 Optional Parts List 13 Warranty 14 4201 Lien Rd Madison WI 5...

Page 3: ... or table DO NOT place the device directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain pan MUST be placed under the unit if installed above a living area or above an area where water leakage could cause damage Never operate a unit with a damaged power cord If the power cord is damaged it must be replaced by the manufacturer its ...

Page 4: ...S 80 F 60 RH UNIT QUEST 506 4036600 QUEST 506 277V 4036610 CFM 1350 0 0 WG 1350 0 0 WG POWER 2700 Watts 2700 Watts SUPPLY VOLTAGE 220 240 VAC 1 Phase 60 Hz 277 VAC 1 Phase 60 Hz CURRENT DRAW 11 0A 10 0A RATED CURRENT DRAW AMPS 104 F 36 13 6A 12 2A ENERGY FACTOR 3 8 L kWh 3 8 L kWh OPERATING TEMP 56 F Min 95 F Max 56 F Min 95 F Max WATER REMOVAL EFFICIENCY 506 Pints Day 8 1 Pints kWh 506 Pints Day ...

Page 5: ... test These test should be performed by a qualified service person The Quest 506 dehumidifier plugs into NEMA 6 20R rated receptacle The Quest 506 277v dehumidifer plugs into a NEMA L7 20P rated receptacle The amp draws are listed on page 4 of this manual Connecting to electrical power must comply with all national state and local electrical codes A ground fault interrupter protected circuit is re...

Page 6: ...thin 2 Vent Place vent after the trap Vent should be open Height of vent should be higher than drain outlet Cap A clean out can be placed before trap but must be sealed with a cap Drain Line Drain line should go in a downward slope to the drain 1 4 drop per foot 4 4 HANGING DIAGRAM PARTS NEEDED 4 pieces 3 8 threaded rod not included 4 3 8 threaded jam nuts not included WARNING Hanging installation...

Page 7: ...ent by the remote humidistat signals the fan or fan and compressor to actuate QUEST CONTROL OPTIONS Cloud Control Quest DEH3000R Honeywell Humidipro Any 24V signal to Dehumidify CAUTION Low Voltage Hazard Can cause equipment damage Disconnect power before beginning installation 5 2 24VAC WIRING The terminal block low voltage circuit breaker and power switch are located on the intake side of the un...

Page 8: ... C FAN R DHUM COMPRESSOR AND FAN FLOAT FLOAT 24VAC COMP FAN QUEST DEH 3000R CONTROLER C FAN R DHUM COMPRESSOR AND FAN FLOAT FLOAT C FAN R DHUM COMPRESSOR AND FAN FLOAT FLOAT QUEST 6 SERIES UNIT 2 C FAN R DHUM COMPRESSOR AND FAN FLOAT FLOAT QUEST 6 SERIES UNIT 3 QUEST 6 SERIES UNIT 1 NOTE DO NOT WIRE IN FAN TERMINAL WITH THIS APPLICATION C FAN R DHUM COMPRESSOR AND FAN FLOAT FLOAT 24V IN COM 24V OU...

Page 9: ...ECHNICAL DESCRIPTION NON STANDARD PATENTED The Quest 506 Dehumidifier uses a refrigeration system similar to an air conditioner s to remove heat and moisture from incoming air and add heat to the air that is discharged Hot high pressure refrigerant gas is routed from the compressor to the condenser coil The refrigerant is cooled and condensed by giving up its heat to the air that is about to be di...

Page 10: ...t as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air filter dirty 5 Defective defrost sensor 6 Low refrigerant charge 7 Air leak such as loose cover or ducting leaks 8 Defective compressor 9 Restrictive ducting 10 Optional Condensate Pump Safety Switch open Test to determine if th...

Page 11: ... location Intake and exhaust ducting should have a minimum of 4 feet from the unit before any turns CAUTION Do not connect with a static pressure greater than 25 wg Contact technical support for additional details Optional duct kits are available from the factory Exhaust Kit 4038641 and Intake Kit 4038642 See figures below for plenum dimensions and duct diameters Alternatively licensed contractors...

Page 12: ...12 QUEST 506 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS QUESTCLIMATE COM 877 420 1330 WIRING DIAGRAM OF THE QUEST 506 DEHUMIDIFIER ...

Page 13: ...4037703 04 COIL EVAP 15 4037704 02 COIL CONDENSER 16 4037707 TXV 3 TON 17 4037708 FAN MOTORIZED IMPELLER 4042941 FAN MOTORIZED IMPELLER 277V 18 4037728 CORD 4042899 CORD 277V 19 4038135 HANDLE POCKET 20 4038136 BEZEL HANDLE 21 4038178 WIRE HARNESS 22 4038079 LUG GROUND 23 4038219 FOOT RUBBER 1 25 DIA 24 4038225 01 BRACKET FOOT RIGHT 25 4038226 01 BRACKET FOOT LEFT 26 4038215 BLOCK WIRING 27 403969...

Page 14: ... means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control LIMITATIONS AND EXCLUSIONS If any Quest 506 Dehumidifier part is rep...

Reviews: