Expanded operating temperature restrictions
30
Expanded operating temperature
Specifications
NOTE:
Outside the standard operating temperature
(10°C to 35°C), the system can operate down to –
5°C or up to 45°C for a maximum of 1% of its annual
operating hours.
For temperatures between 40°C and 45°C, de-rate
maximum allowable temperature by 1°C per 125 m above
950 m (1°F per 228 ft).
NOTE:
When operating in the expanded temperature range, system performance may be impacted.
NOTE:
When operating in the expanded temperature range, ambient temperature warnings maybe
reported
on the LCD panel and
in the System Event Log.
Expanded operating temperature restrictions
•
Do not perform a cold startup below 5°C.
•
The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
•
160 W or higher wattage processor is not supported.
•
Redundant power supply units are required.
•
Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
•
The 3.5-inch hard drive chassis supports a maximum of 120 W processor.
•
The 2.5-inch hard drive chassis supports a maximum of 145 W processor.
•
Only SSDs are allowed in the hard drive slots at the back of the 3.5-inch hard drive chassis.
•
Mid drive configurations, eight 3.5-inch and eighteen 1.8-inch SSD configurations are not supported.
•
GPU is not supported
•
Tape backup unit (TBU) is not supported.