Airflow on high speed with all filters clean and no ducting is slightly over 500 CFM. The unit can be run with very dirty 

filters and virtually no flow without harming the unit. The operator’s decision to change filters should be based on filter 

cost vs. the unit’s filtering effectiveness. If airflow is 250 CFM vs. 500 CFM, the unit will filter particles from a space at 

half the rate. The operator must judge if that is acceptable.

If the operator determines the filters should be changed due to low airflow, it is most economical to change them in the 

following order:

Change the pre-filter (top) first. This is the least expensive filter. Recheck the airflow. If the airflow is acceptable, no 

other filters need to be changed.

If the airflow is still too low, the HEPA filter must be changed. To remove the HEPA filter, follow these steps:

1.  Loosen the eight screws one revolution

2.  Rotate all eight clips out of the way.

3.  Remove old filter. 

4.  Installing the new filter is the reverse of these instructions

4.2B Optional Activated Carbon/Potassium Permanganate Filters

Optional gas phase filters are available from Therma-Stor. They use a blend of activated carbon and potassium 

permanganate. This blend removes the vast majority of gaseous contaminants encountered in most filtering applications. 

The activated carbon removes the heavier volatile organics while the potassium permanganate removes lower molecular 

weight contaminants. This is well suited to the smoke odors present after fire damage.

The life of the media blend depends upon both the hours used and the contamination level. Another advantage of the 

blended media versus activated carbon only is that part of the blend changes color as it loads up with contaminants. It 

starts out black, then turns pink, then brown, and finally white. It is best changed when it passes the brown stage and 

begins to turn white. It has lost most of its effectiveness at that point.

The filter is the same size as the pleated fabric filter. Install it in place of the pleated fabric filter.

5. Service

CAUTION: Servicing the Quest H5 HEPA System with its high voltage circuitry presents a health 

hazard that could result in death, serious bodily injury, and/or property damage. Disconnect the 

appliance from the power supply before servicing. Only qualified service people should service this 

unit.
5.1 Warranty

A warranty certificate has been enclosed with this unit. Read it before any repair is initiated. If a warranty repair is 

required, call the factory first at 1-800-533-7533 for warranty claim authorization and technical assistance.

Optional Parts
4024936 

Duct, Lay Flat, 14” x 250’

Summary of Contents for H5

Page 1: ...ested engineering principles and has passed a thorough inspection for quality of workmanship and function Installation Operation and Maintenance Instructions Read and Save These Instructions 1 Quest H...

Page 2: ...tlet Ducting 3 3 3C Negative Air Ducting 3 3 4 Power Speed Control 3 3 5 Resettable Circuit Breaker 4 3 6 GFCI Protection and On Board Duplex VAC Outlet 4 3 7 Servicing 4 4 Maintenance 4 4 1 Air Filte...

Page 3: ...et One foot minimum distance to obstructions Indoor use only Do not use as stool or bench Do not operate with damaged cord or plug Do not run cord under carpeting Do not cover cord with throw rugs run...

Page 4: ...an cause those devices to backdraft This can contaminate the space with potentially fatal gases In such cases the Quest H5 HEPA System must be used in one of the following three ways A As a filtering...

Page 5: ...CI When the Quest H5 is first turned on check for excessive vibration If the unit vibrates excessively or if impeller rubs on housing turn off the unit immediately Have a service technician inspect th...

Page 6: ...y use a blend of activated carbon and potassium permanganate This blend removes the vast majority of gaseous contaminants encountered in most filtering applications The activated carbon removes the he...

Page 7: ...ller Fan Speed Control 6 4032143 Impeller Fan Speed Control Knob 7 4037569 Cord 14ga 25 8 4033031 08 Run Capacitor 20 mfd 370 VAC 9 4031861 10 Lay flat duct collar ring Optional Parts Item Part No Des...

Page 8: ...Quest H5 Installation Operation and Maintenance Instructions 8 1 877 420 1330 www QuestClimate com info QuestClimate com...

Page 9: ...her cause beyond Therma Stor LLC s reasonable control If any Quest H5 part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be...

Reviews: