1-866-413-5214
Quest Oil Fired CHH-980 Installation, Operation and Maintenance Instructions
7
quest
quest
www.QuestProtect.com
sales@QuestProtect.com
3.4 Circulation Pumps (2 required):
(Fig. 8)
• The HTF circulation pumps are stainless steel, direct drive centrifugal type.
• They are located inside the enclosure at the opposite end to the burner and can be accessed through a pair of
hinged lockable doors (Fig. 1).
• A panel-mounted pressure gauge is connected to the output side of the HTF pump manifold by means of a
1/8” ID hydraulic hose and fittings (Fig. 28).
• See chart (Fig. 7) for specifications.
8: Fluid circulation Pumps
CHH-980
Wayne Burner Model
FH
Operational Mode
ON/OFF
Electrical Characteristics
V-A-Hz-Ph
120/11.5/60/1
Nozzle: Delavan Part #
2 required
2.75-60°B
Fuel Pump Pressure
PSI (Kpa)
162 (1117)
Fuel Input Rate: factory set
USGPH (Liters/Hr)
7.0 (26.5)
Heat Input: based on 140,000 Btu per USG
Btu/H (Kw/H)
980,000 (287)
Heat Output: @ 80% net efficiency
Btu/H (Kw/H)
784,000 (230)
2 Pumps required
CHH-980
Goulds Pump Model
1ST1F1B4
Impeller Diameter
inches
5.75
Motor Horsepower
HP
1.5
Voltage Choice
Volts
120/240
Full Load Amp Rating
Amps
16.6/8.3
System Design Flow Rate, using 1 pump
US GPM
35
System Design Flow Rate, using 2 pumps
US GPM
70
System Design Operating Pressure
PSI
35 to 45
(Fig. 7)
(Fig. 6)