20
Nozzle 3
Once the nozzle 3 comes to run the program, the output is in
conducting state, or else not.
Nozzle 4
Once the nozzle 4 comes to run the program, the output is in
conducting state, or else not.
Ready flag
When the unit comes into the normal ready state, the output is in
conducting state, namely, once receiving the “START” signal, it
comes to run. And it closes the output after running.
Alarm flag
When set the mode as alarming, once it detects the abnormal state,
the output is in conducting state, or else not.
Working flag
When the unit comes into the working state, the output is in
conducting state, or else not.
Work End flag
After t finishing the process, the output is keeping in conducting
state 200ms, or else not.
Cylinder
Once the unit comes to run the cylinder process, the output is in
conducting state, control cylinder motion, or else not.
Clean output
Once the unit comes to run the clean process, the output is in
conducting state, do the clean (blowing or revolving brush), or else
not.
Pause output
The condition of pause BTN
Left LED
The condition of left light on key box
Right LED
The condition of right light on key box
Emer Output
The condition of emergency stop
Reset Output
The condition of reset
EnNozzleAdj
Enable nozzle calibration signal
Note:
The function settings of input & output cannot be accessed by the operator. It can only be
operated by the manufacturer.
Will not give advanced information if some functions are changed.
3.6 Debugging steps
3.6.1 Security check before operation
Inspect the line and do NOT power on if line was damaged or wet. Please invite the professional when
the device needs maintenance.
Attention high voltage, prevent electric shock.
User must inspect current and pneumatic station after installment or before first time using.