25
5
Lack material alarm*
A/B/C/D
Stop immediately
6
Block material alarm*
A/B/C/D
Stop immediately
Caution
:
If it was interrupted by emergency stop, you can continue after dismiss the emergency stop and reset.
The above “interrupt type” is effective in the processing mode, and at the teaching mode and debugging
mode, the “interrupt type” with “*” is ineffective.
A/B/C/D is interrupted mark, these mean:
Interrupt
mark
Interrupted station
Continue station
A
From Start feeding to dispensing
process finish.
Jump interruption dispensing point, and go
straight to next point.
B
Moving between two dispensing
points.
Go straight to next dispensing point.
C
Pause
Go to next dispensing point.
D
Holding
up
distance
after
dispensing process.
Go to next dispensing point.
Caution: If power outages during the operation, it cannot continue the interrupted work after