8.1.4 Functional sequence 2 (<799> = 2) without stop after seam end (<603> = II)
Functions:
fast scissors at start
fast scissors at end
chain vacuuming at start
chain vacuuming at end
thread tension release at start and at end
Switch condition of the keys at the
OC-TOP
:
Key
T9
(P/M) off (dark)
Key
T10
(T/E) off (dark)
Key
T6
on (bright)
Key
T7
on (bright)
Key
T11
on (bright)
Key
T12
on (bright)
Key
T15
on (bright)
Q-41-MSII-2-EN
8.6
02-02-21
max
bright
dark
0
0
1
1
0
0
- 2
12 D
Pedal
LS
n
(CD)
S 2
<105>
<110>
1
0
(AB)
S 1
<105>
(AB)
S 1
ML
KESAU
FSL
<540>
<542>
<540>
*
Outp. A8
*
. A5
Outp
*
. A6
Outp
1
1
0
0
*
. A1
Outp
*
. A10
Outp
SSVW
SSRW
<112>
<112>
<112>
Motor runs
Fast scissors forward
Fast scissors backward
Thread tension release
Chain vacuum
*
see electrical connections diagram page 12.2
Fig. 8.2b