Q-41-MSII-2-EN
9.14
02-02-21
9.2.5 Reset
Any parameters having been modified from their original (standard) condition can be restored to their standard
condition by „
reset
“.
Exceptions:
Parameters 700, 799, 800 and some further parameters identified by „
4
“ in the list of parameters. For these
parameters, the conditions programmed by the user will be maintained even after a „
reset
“ is performed.
Reset Procedure
- Turn OFF power switch
S1
.
- Toe the treadle fully forward and hold in that position.
- Press and hold keys
M-
and
V-
simultaneously.
- Turn ON power switch
S1
.
- Stop pressing keys and stop toeing the treadle.
Response: Indication 6
To make „reset“, subsequently press key
M+
.
If it is intended not to make a „reset“, press key
M-
.
Subsequently, the display will show the indication 1.
T
SE
/-
RE
+
05
05 A