QUICK2025 manual operation
8
、
Parameters Setting
Interface Setting
A
.
MAIN
(
current process setting
)
B
. SYSTEM
(
system setting
)
C
.
DATA
(
parameters setting
)
A
、
MAIN
Current Process Setting
(
with keyboard
)
It is necessary and must to adjust the parameters when de-solder firstly PCB and BGA. Operation steps are
as follows.
For example: setting the temperature of TEO is 95
℃
(former temperature is 80
℃
)
TC and TB show room temperatures in initial state. Press “SET” key to select the “T0:080
℃
”and then
press “SET” key again into the setting state. Cursor is in the 1’s digit of the selecting item.
Pressing “UP” or “DOWN” key to change the value of the 1’s digit as“5”, and then pressing “LEFT” key to
make the cursor move forwards one digit. Pressing “UP” or “DOWN” key again to change the ten’s digit “9”.
Press “SAVE” key to save the data. Press the “SAVE” again to exit the parameter setting state if only need to
set the “TO” and then press “RIGHT” key to the next parameter setting.
Page 13