QUICK2025 manual operation
Page 16
The soldering technics is decided by T0
、
TB1
、
TB2
、
T1
、
T2
、
T3
、
S1
、
S2 and S3. It describes the temperature
graph during the period of the system working. TL means Melting temperature of solder and the range between
T2 and T3.
T0
T0 is the valve temperature of the bottom heater required by the top heater heating. Also it is the first
temperature of this technics process. When the working flow begins, the bottom heater starts to heat up and the
top heater begins to heat up after the temperature up to T0.
TB1
、
TB2
TB1
:
The setting temperature of the bottom before the T2
TB2
:
The setting temperature of the bottom after the T2
T1
T1 is the heat preservation starting temperature of reflow soldering. It is also the second temperature of this
technics process. The temperature rises to T1 with a proper speed of the electronic elements permitting. Use the
UP
, DOWN, RIGHT, LEFT, RIGHT, SET and SAVE key to set the values of T1 when modifying the
parameters.
T2
It is the temperature when finishing the heat preservation of reflow soldering. The pre-heating temperature rises
to T2 when to the time S1. During this time, PCB and component pre-heating is finished and the solder is
activated. Use the
UP
, DOWN, RIGHT, LEFT, RIGHT, SET and SAVE key to set the values of T2 when
modifying the parameters.
T3
It is the peak value temperature of reflow soldering. When the temperature reaches T2, the temperature equably
rises to T3 with a definite raising speed. The soldering or de-soldering will be finished when the temperature
reaches to the peak value and performs the next step. Use the
UP
, DOWN, RIGHT, LEFT, RIGHT, SET and
SAVE key to set the values of T3 when modifying the parameters.
TL
Melting temperature of solder. At this temperature, the solder starts to melt down and turn into liquid.
During the soldering and de-soldering, users can press CAL Key to calibrate the value of TL when the solder do
not turn into liquid or do not turn into liquid on time. Use the
UP
, DOWN, RIGHT, LEFT, RIGHT, SET and
SAVE key to set the values of TL when modifying the parameters.
S1
Heating time rises from T1 to T2. User can set the value in the range of 0~300s.
S2
Heating time rises from T2 to T3. User can set the value in the range of 0~300s.
S3
Prolonged heating time (heat preservation time) after the temperature reach T3, and user can also set the value