10.
Calibrating the System
Due to vibrations during transporting, it is necessary to calibrate the system before using. The steps are
shown as follows.
10.1
Checking the Calibration
1
.
Insert the calibration plate into the PCB fixture and adjust the position, lock the fixture.
2
.
The vacuum tube section of vacuum pump will be treated as the calibration hole. (If it has nozzle, please
remove it.)
3
.
Press T-H
(↓)
key to make top heater move down.
4
.
Turn SUCKER
(↓)
to lower the calibration tube. Check whether the calibration tube superposes exactly
with the round hole on the calibration plate. If they aren’t superposition, please adjust Micro-adjustment
Knobs of fixture until the calibration tube and hole completely superpose. After superposing, please don’t do
any change to the calibration plate or calibration tube.
5
.
Press T-H
(↑)
to make top heater moving up.
6
.
Press “CAM-CON” to make the camera in alignment state and then adjust the image displayed by
Keyboard. Observe the images: the system is precise if the two images (Circle) in the Monitor superpose,
otherwise not. The system needs to be adjusted.
Imprecise
Precise
10.2 Adjusting the alignment
1
.
Take out the cover of the alignment arm.
2
.
Use spanner to adjust the two adjusting screws on the front board, the adjusting extent can not be too large,
until the two round images superpose on the display.
3
.
Locking the adjusting screws on the left .