QUICK2025 manual operation
Page 7
To the monitor interface or
the video interface
To the interface RS232
of the PC
To the power
supply socket
Turn on the switch of the power supply after connecting all the units and cords.
7
、
Parts Instruction
*
SENSOR
The system has five K type sensors checking the temperature of the point in the PCB, such as the temperature of
BGA surface, bottom temperature of the PCB, real temperature of the tin ball. And these values can show on the
LCD. Besides, users can select the sensors during KT1-KT5 by “TOS”.
The system is a closed loop temperature controlling. Testing the temperature of BGA surface with infrared
temperature sensor. Besides bottom sirocco and infrared heater test the temperatures with other K sensors.
*
TOP HEATER
The power of the top infrared heater is controlled to satisfy the different needs and only one of it is normally
opening and others are controlled by the three switches on the faceplate.
One group of the top infrared heater near the inside is usually opening without switch controlling and the power
is 240W. When enhancing the power of the top heater, set the switch of the “TOP HEATER” as “ON”. The
power enhances 240W every opening one group heating tubes.
K type sensors
Controlling switches of top heater