QUICK EA-A10 OPERATION MANUAL
Page 4
19. Dimension
:
1200(L) mm
×
800(W) mm
×
940 (H)mm
20. net weight
:
about 60kg
5.2 Technical Parameter
T0: Valve temperature and T0
≤
TIR. Only when the temperature of the bottom infrared heater up to the T0, the
top and bottom hot air heater comes to heat.
VT: The setting airflow of the top hot air
VB: The setting airflow of the bottom hot air
Top Sirocco: set top sirocco temperature of flow
Bottom sirocco: set bottom sirocco temperature of flow
Time: The setting time in the D1~D6&COOL zone
D1~D6
:
The six zone of one flow
COOL
:
The cooling zone
KT1~KT5: The testing temperature on the PCB with the outer K-type sensor 1~5
TC
:
The real temperature of the top sirocco heater
TB
:
The real temperature of the bottom sirocco heater
Tir
:
The setting temperature of bottom infrared heater
TIR
:
The real temperature of the bottom infrared heater
BUM
:
Pump is in working mode or not
FAN
:
The nearside cooling fan is in working mode or not
HED
:
the position of the top heater
(
UP-DOWN-UNKN
)
ALG
:
the position of the contraposition arm
(
IN-OUT-UNKN
)
6. Installing and Connecting of the Equipment
6.1
Check the Package of the Equipment
Check the package of the equipment is good or not.
Take out the QUICK EA-A10 from the package and place it on the solid working desk.
Check every unit is good or not according to the packing list. If not, please replace the unit from our company
or agents in time.
6.2
Connect Equipment
Check the power supply whether is the same with the rating voltage value in the specification scutcheon.
Check the switches of the entire units are turn off or not.
Connect the power cord to the power socket.
Connect the RS-232 cord to the RS-232 socket in PC if you use the BGA software.
Connect the video line of the external LCD to the VIDEO-OUT socket.
Connect the K type sensors (optional) to the external sensor
’
s socket in the front.