background image

15

GB

DP1 300/500W - REV001B

WARNING

WARNING:

 stay clear of the chains, ropes and gypsy. Make sure the electric motor is off when windlass is used manu-

ally (even when using the handle to disengage the clutch). In fact people with windlass remote controls (hand-held re-
mote control or radio-controlled systems) might accidentally operate it.

WARNING

:

 secure the chain with a device before starting the navigation. 

WARNING

:

 do not operate the windlass by using the electrical power when the handle is inserted in the drum or into 

the gypsy cover.

WARNING

:

 Quick

®

 recommend using a circuit breaker designed for direct current (DC) with delayed-action (thermal-

magnetic or hydraulic-magnetic) to protect the motor supply line from overheating or short circuits. The circuit breaker 
can be used to cut off power to the windlass control circuit and so avoid accidental activation.

CLUTCH USE

The clutch (5) provides a link between the gypsy and the main shaft (11 or 12). The clutch can be released (disengagement) 
by using the handle (1) which, when inserted in the bush (2) of the drum or into the gypsy cover (4), must be turned counter-
clockwise. The clutch will be re-engaged by turning it clockwise (engagement). 

WEIGHING THE ANCHOR 

Turn on the engine. Make sure the clutch is engaged and remove the handle. Press the UP button on the control provided. 
If the windlass stops and the hydraulic magnetic switch (or thermal cutout) has not tripped, wait a few seconds and try again 
(avoid keeping the button pressed). 
If the hydraulic magnetic switch, has tripped, reset it and wait a few minutes before weighing anchor once again. 
If, after a number of attempts, the windlass is still blocked, we suggest to move the boat to release the anchor. Check the up-
ward movement of the chain for the last few meters in order to avoid damages to the bow. 

CASTING THE ANCHOR 

The anchor can be cast by using the electrical control or manually. To operate manually, the clutch must be disengaged allow-
ing the gypsy to revolve and letting the rope or chain fall into the water. To slow down the chain, the handle must be turned 
clockwise. 
To cast the anchor by using the electrical power, press the DOWN button on the control provided. In this manner, anchor cast-
ing is under control and the chain and rope unwind evenly. 
In order to avoid any stress on the windlass -once the boat is anchored- fasten the chain or secure it in place with a rope.

USAGE

Summary of Contents for Prince DP1 Series

Page 1: ...d uso SALPA ANCORA VERTICALI User s Manual VERTICAL WINDLASSES Manuel de l utilisateur GUINDEAUX VERTICAUX Benutzerhandbuch VERTIKAL ANKERWINDEN Manual del usuario MOLINETES VERTICALES DP1 SERIE PRINC...

Page 2: ...ristiques techniques Pag 21 Installation Pag 22 Sch ma de cablage Pag 23 Utilisation Avvertissements importants Pag 24 25 Entretien Pag 26 27 Groupe Seite 28 Technische Eigenschaften Seite 29 Montage...

Page 3: ...D 2 EXAMPLE DP1524 a a a a a a a 85 3 7 32 271 9 5 8 61 2 13 32 69 2 23 32 181 7 23 32 122 4 11 16 134 4 5 9 32 75 4 2 31 32 DIMENSIONS OF MODELS mm inch DP1 300 500W D For the gypsy codes please con...

Page 4: ...KAGE CONTAINS windlass on deck unit motorgearbox reversing contactor unit base gasket drill template handle bolts and screws for assembly user s manual conditions of warranty TOOLS REQUIRED FOR INSTAL...

Page 5: ...page 12 REVERSING CONTACTOR UNIT MOD T6415 12 12V MOD T6415 24 24V C A2 FOOT SWITCHES MOD 900U AND 900D BLACK BROWN BLUE A1 FUSE 4A 12V 2A 24V BROWN BLACK BLUE L L1 L2 L3 L4 L5 L1 L2 L3 L4 L5 CONNECTI...

Page 6: ...ned counter clockwise The clutch will be re engaged by turning it clockwise engagement WEIGHING THE ANCHOR Turn on the engine Make sure the clutch is engaged and remove the handle Press the UP button...

Page 7: ...6 24 25 27 29 28 20 17 18 23 26 19 POS DESCRIPTION CODE 1 Straight windlass lever nylon PVLVSDN00000 2 Bush SGMSD0400000 3 Drum MSE050000R03 4 Gypsy cover ZSPMSGB05R03 5 Clutch cone DP1 MSFDP1000000 6...

Page 8: ...r and the reversing contactor unit grease them POS DESCRIPTION CODE 10 Bearing MBJ160040000 11 Shaft DP1 MSASDP100R00 12 Shaft DP1 D MSASDP1D0R00 13 Key 6 6 25 MBH060625X00 14 Key 6 6 50 MBH060650X00...

Page 9: ...DP1 1 4 D FVSSTDP1D001A00 OSP TOP DP1 6MM D FVSSTDP1D006A00 DRUM DP1 CODE OSP WINDLASS DRUM 500W 50MM FVSSMSE04000A00 COMPLETE BASE DP1 CODE OSP WINDLASS BASE SERIES DP1 COMP FVSSBDP110C00A00 OSP CHA...

Page 10: ...V QUICK FVSSR0512Q00A00 OSP MOTORGEARBOX 500W 12V QUICK HS FVSSR0512QHSA00 OSP MOTORGEARBOX 500W 24V QUICK FVSSR0524Q00A00 OSP MOTORGEARBOX 500W 24V QUICK HS FVSSR0524QHSA00 ELECTRIC MOTOR CODE OSP EL...

Page 11: ...BOARD MOD 800 L L1 L2 L3 L4 L5 SENSOR MOTOR FUSE 4A 12V 2A 24V BATTERY HYDRAULIC MAGNETIC CIRCUIT BREAKER see table on page 4 12 20 28 36 C A2 A1 REVERSING CONTACTOR UNITS MOD T6415 12 12V MOD T6415 2...

Page 12: ...NOTE NOTES NOTES NOTIZEN NOTAS...

Page 13: ...NOTE NOTES NOTES NOTIZEN NOTAS...

Page 14: ...39 0544 415047 www quickitaly com E mail quick quickitaly com Codice e numero seriale del prodotto Product code and serial number Code et num ro de s rie du produit Code und Seriennummer des Produkts...

Reviews: