4 - Safety

4.0 - Precautions

• Comply with all the safety warnings included in this manual.

• Comply with all the technical parameters indicated in this manual.

• Handle with care paying attention to avoid damaging the gyro or getting injured.

• Strictly observe all the local accident prevention standards during both assembling and regular operation.
• Maximum cleanliness must be guaranteed during operations.

BEFORE USING THE GATEWAY QNN CAREFULLY READ THIS USER’S MANUAL. IF IN DOUBT, IMMEDIATELY 
CONTACT YOUR NEAREST AUTHORISED QUICK® DEALER.

4.1 - Warnings

• The QNN operates within 90÷32 Vac power supply

Connect to the electrical line in compliance with the protection standards in force.

• 

During navigation, we recommend not disconnecting the power supply to prevent damages to 

the connected products.

• DO NOT open the device case.

• DO NOT introduce foreign objects inside the protection cover.

• 

Before performing any operation, such as 

cleaning or a update software,

 in order to prevent any 

damage to people or objects caused by an accidental start-up. Disconnect the 

Gateway QNN from the 

power supply.

• Restore the power supply only after having correctly installed all the safety devices that were removed to 

carry out the operations.

CLEANING THE APPLIANCE

• DO NOT USE 

solvents or fuels to clean the appliance.

• DO NOT REMOVE 

the safety labels on the equipment.

4.2 - Environmental requirements

We recommend positioning the stabilizer in a dry, ventilated place in order to enable it to operate at full power and

be protected from atmospheric agents.

Make sure that the installation location is suitable for correct installation and easy inspection.

Do not use this product as a primary navigation instrument. The operator is responsible for the use 

of the accessories on the QNN and prudent methods for safe navigation.

 The software contained in 

the QNN could change without notice or may not be updated. The alarms refer to the use of the individual 

connected accessories and to the use of the QNN

You are aware and accept to be the only persons responsible for use of the QNN and all decisions taken as 

a result. In using this service, you free Quick SpA and waive presenting any claims in relation to this service.

The QNN does not replace standard navigation practices and must not be used as single sources of 

reference. The QNN is only a navigation aid and must be used along with approved methods for safe 

navigation. The captain of the ship is always responsible for the course correction.

All navigation aids are subject to inaccuracies and discrepancies that, if not taken into consideration, can 

cause accidents and problems and, consequently, the loss of life or serious injuries.

F

Summary of Contents for QNN

Page 1: ...REV 000A Gateway QNN INSTALLATION AND USE MANUAL EN Pag 4 GATEWAY QNN INTERFACE a a m Gyro 1 Speed 0...

Page 2: ......

Page 3: ...ay Installation Pag 9 6 Electrical connection Pag 10 7 Functioning of the appliance Pag 14 7 0 Control Panel Pag 14 7 1 LED specifications Pag 14 8 Installation on Chartplotter Pag 15 8 0 Installation...

Page 4: ......

Page 5: ...functions Compatible Quick accessories Anchoring system Thruster Battery chargers Stabilazer MC Quick Gyro Lighting 1 1 Main features Management of Quick accessories Compact and practical design inte...

Page 6: ...Serial port RS 485 CAN bus port 2 optical isolation 1kV LED indicators 5 Power Ethernet status RATING Supply da 9 a 32 Vdc Current absorption 0 15A max at 24 Vdc ENVIRONMENTAL CHARACTERISTICS Operatin...

Page 7: ...errors in translation between the translated version and the original text in the Italian language reference will be made to the Italian text This document contains the instructions that are necessar...

Page 8: ...tions CLEANING THE APPLIANCE DO NOT USE solvents or fuels to clean the appliance DO NOT REMOVE the safety labels on the equipment 4 2 Environmental requirements We recommend positioning the stabilizer...

Page 9: ...iteria The appliance must be positioned so that it can easily be reached by the operator Choose a clean smooth flat location The fastening points should be on a level surface The holes must not weaken...

Page 10: ...2 ETH 1 PORT GYRO STABI 5 USB PORT SOFTWARE UPGRADE 3 CAN 1 PORT CHC SRC NRG INVERTER 6 CAN 0 PORT PCS SYSTEM ANCHORING SYSTEM THRUSTER CONNECTION OF GATEWAY QNN ALIMENTAZIONE 4 9 9 9 8 8 8 1 5 2 6 3...

Page 11: ...CRIPTION 1 SHIELD 2 3 GND 4 CAN H 5 CAN L PIN DESCRIPTION 1 TX 2 TX 3 RX 4 RX 5 SHIELD PIN DESCRIPTION COLOR 1 RTS TX 1 BROWN 2 TX 1 BLUE 3 CTS RX 1 WHITW 4 RX 1 GREEN 5 RX 2 NOT INCLUDED YELLOW 6 CTS...

Page 12: ...M M CAN TERMINATOR F A RC REMOTE CONTROL MC Quick Gyro B Control CHC when terminator is not built in C LDIM BUS RGBW D Battery charger E PCS Gateway E PCS Gateway Proportional control PCS system ANCH...

Page 13: ...l PCS NCG T Gateway Thruster PCS NCG W Gateway windlass ANCHORING SYSTEM 0 0 meter V out 0 0 V 0 0 m I out V out 0 0 V 0 0 m I out 0 0 rolling reduction BATTERY CHARGERS SINE WAVE INVERTER LIGHTING TH...

Page 14: ...Y CONNECTED LED POWER GREEN LED STATUS DESCRIPTION OFF GREEN OFF NO POWER ON GREEN ON OPERATING MODE OPERATION COMPLETED SUCCESSFULLY GREEN FLASHES SLOWLY ERROR DURING THE LAST OPERATION GREEN FLASHES...

Page 15: ...mpleting the electrical connections just connect the Gateway to the Chart plotter Thanks to the plug play system all of the calibrations made on the Quick products systems or from the chart plotter ar...

Page 16: ...ctions The detailed instructions for use can be found in the following In Home it shows the general settings in each page it shows the settings for the page shown QNN ICON 10 0 Start QNN After perform...

Page 17: ...ucts connected in the active inactive phase The Quick accessories that can be applied to the QNN are Windlass Thrusters Gyroscopic Stabilizers Battery Charger Inverter currently not available Lights A...

Page 18: ...t of measure 3 save load setting Backup Use a formatted USB drive to perform the backup insert the drive and press SAVE The backup was successful if the folder is found on the drive 4 Clear device lis...

Page 19: ...chor Quick control panels can be connected to the PCS family version 62 37 and the CHC version 2 15 and later for use and installation of the control panels refer to the dedicated manuals PCS CONNECTI...

Page 20: ...hor 4 Zero set key Reset the measure of chain lowered This option is to be used during installation or when the chain counter s reading does not match the actual length of the chain lowered 5 Setup An...

Page 21: ...unctions 2 Manoeuvring keys with proportional control Proportional power manoeuvring control keys choice of 25 50 75 and 100 power possible only with L R bow rotation and L R stern rotation keys 3 Blo...

Page 22: ...Gyro Angle Precession angle 4 ON OFF Button Key to turn on the gyroscope if single gyroscopes with the multi stabilizer option 5 Gyro sliding bar List of connected gyros and status display 6 Setup Gyr...

Page 23: ...eral battery chargers at the same time More information Manual RDS NR DESCRIPTION OPERATION 1 Status Indication of the battery charger status 2 Mode Charging characteristics Float Absorption Bulk Char...

Page 24: ...tion 5 Power OFF orange By keeping this button pressed for 2 seconds all zones are simultaneously turned OFF 6 Men functions This button allows accessing the MENU functions 1 Extra access to further s...

Page 25: ...rea management page changes according to the type of light source Pay attention to the selection 7 Selection of light source type Based on the type of source chosen there are different options Choice...

Page 26: ...er cannot communicate with the QNN make sure the IP address on the RC remote controls is different than the one in the QNN If the two addresses are identical contact Quick customer service for assista...

Page 27: ......

Page 28: ...QUICK S p A Via Piangipane 120 A 48124 Piangipane RAVENNA ITALY Tel 39 0544 415061 Fax 39 0544 415047 www quickitaly com quick quickitaly com REV 000A USER MANUAL Product serial code...

Reviews: