ENGLISH (108-501)
108
10
11
12
13
LOADERS
Fitting
The implement rams of the loader are equipped with
safety valves, mounted on the loader cross tube. Fig.10
illustrates the safety valve on loaders without SELECTO.
The SELECTO is equipped with corresponding (built-in)
safety valves (see fig.11).
Note !!
An electric connector for the connection of SELECTO is
included in the ERGODRIVE-kit.
Install the connector on the right subframe (fig.12) and
connect to the current source (12V). Connect earth wire
to tractor body.
Connect the cable from the electric control device to the
connector according to the wiring diagram (fig.13). The
leaders are marked 1,2,3.
WARNING !
Incorrect installation of the cables may destroy the built-
in diodes in the connectors of the valve (SELECTO).
Please study the mounting instruction supplied with the
SELECTO-kit.
Lift the front of the tractor and check that its wheels and
mudguards don't interfere with loader and subframe at
max. turning angle and oscillation.
Since the loader has been tested on tractors of a certain
type (see the List of Subframes) as concerns the hydrau-
lics, cabs, wheel size, mudguards etc, this means that
use with tractors other than these may need special
measures to be taken when attachment is made.
Summary of Contents for Q 910 US
Page 171: ...125 125 501...