background image

SEE

 

//

 

H E A R

 

//

 

F E E L

THE QUIETCOOL DIFFERENCE

ADVANCED WHOLE HOUSE FANS

®

THE NATURAL CHOICE FOR ENERGY SAVINGS!

OWNER’S GUIDE

SMART ATTIC FAN GABLE

DO NOT THROW AWAY! SERIAL NUMBER FOR FAN IS LOCATED ON 
BACK COVER OF OWNER’S GUIDE. RETAIN IN A SAFE PLACE.

Summary of Contents for AFG Series

Page 1: ...TCOOL DIFFERENCE ADVANCED WHOLE HOUSE FANS THE NATURAL CHOICE FOR ENERGY SAVINGS OWNER S GUIDE SMART ATTIC FAN GABLE DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON BACK COVER OF OWNER S GUIDE R...

Page 2: ...personnel should service the QuietCool system The user should not attempt to service the product 7 Building Codes Always follow Local Building Codes when installing appliances CONTENTS 1 SYSTEM OVERV...

Page 3: ...ontrol all the settings of your Smart Attic Fan right from your couch With the QuietCool Smart Control App you can see your current attic temperature modify the temperatures for the multiple speeds of...

Page 4: ...y or effectively as it could with 1 750 attic venting But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contract...

Page 5: ...sible for all applications Wide Mount The AFG can be mounted on a wide louver but additional mounting steps must be taken in order for the fan to work properly As shown in Figure 2 1B two additional b...

Page 6: ...o the wood framing around your gable vent See picture for screw locations 3 Repeat step 1 and 2 for the three additional covers 3 WIRING NOTE Wiring Diagrams are for examples ONLY Wiring should be don...

Page 7: ...n wire from the fan and the green wire from the power cord to the ground screw in the Hub 7 Set the dip switch positions inside the Hub as shown in Figure C 8 Power on the Hub The Power LED indicator...

Page 8: ...ink three times every 2 seconds on HIGH blink once every 2 seconds on LOW Three Speed Fan blink three times every 2 seconds on HIGH blink twice every 2 seconds on MED blink once every 2 seconds on LOW...

Page 9: ...an to turn off For example if it is set at 90 the fan will turn off if the humidity in the attic is 90 or higher Turn Fan On This is the humidity percentage that will cause the fan to turn on For exam...

Page 10: ...erage household obstructions Why are all my lights blinking on the hub and nothing is working If you re experiencing blinking lights on all LED indicators on the hub then it is an indication that your...

Page 11: ...hase C This warranty does not cover any of the following 1 Accidental or consequential damage resulting from the operation of our equipment or any malfunction thereof 2 Cost of service calls to diagno...

Page 12: ...ANS QuietCool is Proudly Designed and Built in California 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM Fan Serial Number Information Retain for your records Serial...

Reviews: